Lovibond MD150 6 in 1 photometer – chlorine, pH, cyanuric acid, alkalinity, calcium hardness and bromine – 282150
Pool water stays balanced when chlorine, pH, alkalinity, cyanuric acid and calcium hardness are all in range. With colour tests, every reading depends on the light and on how the colour is read, and a small error in pH or alkalinity ends up as cloudy water, scale or excess chemical use.
The Lovibond MD150 photometer measures all six parameters with tablets and shows the result on screen, with no colour interpretation. It stores the last 100 readings and transfers them to your phone via NFC or to a computer via USB-C.
Parameters and ranges
- Free and total chlorine (DPD No. 1 and DPD No. 3 Evo): 0.02–6.0 mg/L Cl₂.
- pH (Phenol Red Photometer): 6.5–8.4.
- Cyanuric acid (CyA HR-Test): 10–200 mg/L.
- Alkalinity-m (Alka-M Photometer): 5–300 mg/L CaCO₃.
- Calcium hardness (Calcio-H No. 1 and No. 2): 5–500 mg/L CaCO₃.
- Bromine (DPD No. 1): 0.05–13.5 mg/L Br₂.
Technical data
- Optics: LED and spectrometer sensor; photometric range 0–3 Abs; photometric accuracy 3% FS (20–25 °C).
- Vials: round, 13, 16 and 24 mm.
- Zeroing: One-Time-Zero function: the zero stays valid for 8 hours unless the instrument is switched off.
- Calibration: factory and user adjustment, with return to factory adjustment at any time.
- Data: 100-record memory; transfer via NFC (AquaLX app) and USB-C (Lovibond Data Expert software) in .csv format.
- Display: backlit LCD; membrane keypad.
- Protection: IP67.
- Power: 2 AA batteries, approx. 5000 measurements without backlight.
- Dimensions: 155 × 76 × 45 mm.
Contents of the case
- MD150 photometer in carrying case.
- 100 DPD No. 1 and 100 DPD No. 3 Evo tablets.
- 100 Phenol Red Photometer tablets.
- 100 CyA HR-Test tablets.
- 100 Alka-M Photometer tablets.
- 50 Calcio-H No. 1 and 50 Calcio-H No. 2 tablets.
- 3 round glass vials with lids and sealing rings.
- 10 ml syringe, 3 stirring rods, cleaning brush and screwdriver.
- 2 AA batteries and USB-C to USB-A cable.
- Manual, certificate of compliance and warranty information.
Use in the pool
- Quimipool reference values: free chlorine between 1 and 1.5 mg/L, pH between 7.2 and 7.4 and alkalinity between 120 and 140 mg/L.
- Compare cyanuric acid and calcium hardness with the values given by the manufacturer of your products or equipment.
- Zero once and measure all six parameters in a row on the same sample.
Spare parts and accessories (Lovibond code)
- DPD No. 1: 511050BT (100) and 511051BT (250).
- DPD No. 3 Evo: 511420BT (100) and 511421BT (250).
- Phenol Red Photometer: 511770BT (100) and 511771BT (250).
- CyA HR-Test: 511430BT (100) and 511431BT (250).
- Alka-M Photometer: 513210BT (100) and 513211BT (250).
- Calcio-H No. 1 and No. 2: 517761BT (100 each) and 517762BT (250 each).
- Chlorine reference standard kits: 275630, 275631 and 275632. pH 7.45 reference standard kit: 275635.
- MD50/MD150 verification standard kit: 215700.
- USB-C to USB-A cable (1 m): 19820-081.