Hidrólisis 8 Oxilife
Hidrólisis 8 Oxilife Hidrólisis 8 Oxilife Hidrólisis 8 Oxilife

Sugar Valley Oxilife OX 0

ref: 01EQOX0
  • Low salinity hydrolysis + electrolysis equipment.
  • Output: 8 A.
  • Water salinity: 1.5 grams of salt per litre.
  • Removable display.
  • Optional automatic controls: pH, redox, free chlorine, conductivity, temperature.
  • Self-cleaning cell with titanium plates.
  • New model with touch screen
  • Manufacturer: Sugar Valley.
  • Code: OX0.
€1,299.00 IVA included
Free shipping
Free Shipping + info

Bought together Usually

Items: 1
Total price: €1,299.00

Technical characteristics

The treatment that suits your needs

The low salinity hydrolysis and electrolysis set provides maximum cleaning with minimum chlorine production. Its action provides perfect water disinfection with a minimum of salt.

What is salt electrolysis?

  • A new concept to improve water quality.
  • Generates chlorine from the common salt dissolved in the pool water.
  • It avoids the handling of chemicals and simplifies maintenance.
  • Ensures a healthier and more pleasant bathing experience.

Advantages

  • It provides pure water with a minimal dose of salt.
  • Guarantees maximum water cleanliness.

Oxilife Features

  • Removable display.
  • Access menus with security passwords.
  • Safety: lack of flow / lack of salt / cover detection.
  • Disinfection based on hydrogen and oxygen and/or salt.
  • Optional automatic controls for pH (+/-), redox, Cl, conductivity and temperature.
  • Safety: dosing time exceeded.
  • Setpoints, waiting times and dosing configurable with patterns or at a single point.
  • Automatic or manual operation.
  • Compatible with VISTAPOOL remote control by cable or via WiFi.

Private Swimming Pools

Clearly more rewarding.

For greater convenience, all models have a removable touch screen, with wired or Wi-Fi connection to control the water parameters without leaving the house.

SUGAR VALLEY BRANDS, based on the salt electrolysis principle of operation: HIDROLIFE, BIONET

Principle of operation

HYDROLYSIS AND/OR LOW-SALINITY ELECTROLYSIS

Water is composed of 2 parts hydrogen and 1 part oxygen (H2O). Hydrolysis means, etymologically, decomposition by water. Hydrolysis is a process to generate hydrogen and oxygen by means of electricity and water.

When electric current passes through water, the chemical bond is broken, negative charges or oxygen ions migrate to the positive electrode (anode). The positively charged hydrogen ions are attracted to the negative electrode (cathode). The decomposition that occurs is as follows:

Electrical energy +2 H2O --> 2 H2 + O2

This results in an extra negative element, as the number of electrons in the combination exceeds the number of protons by 1. It is now a single negatively charged hydroxide, or hydroxyl ion (OH- ).

In HYDROLYSIS there are numerous secondary chemical reactions, which also produce ionic species with oxidising and disinfecting power, such as ozone (O3), monoatomic oxygen (O1) and hydrogen peroxide (H2O2).

The electronic circuit of our electronic box transforms the current (220 V, 50 Hz) into low-voltage, high-amperage direct current. This current is supplied to noble metal-activated titanium electrodes placed in the recirculating water in a specially designed holder.

In these non-soluble electrodes, a combination of the most powerful oxidants available for water disinfection is created, thus avoiding the use of chemicals.

If in this treatment we incorporate a very small amount of salt (between 1 and 2gr salt per litre of water) either due to a lack of conductivity or because we generally want a tangible residual, we will achieve that the same system also generates a residual of chlorine by saline electrolysis at a low concentration. The products decompose, act and regenerate again. The residual disinfectant generated by electrolysis does not harm the eyes, skin or health of the bather. It does not matter if we run out of salt in the water, as the system will continue disinfecting in HYDROLYSISIS mode. The chlorine generated destroys the organic matter and pathogens present in the water, transforming it back into sodium chloride (common salt).


Oxilife OX 0 Oxilife OX 1 Oxilife OX 2 Oxilife OX 3
Exit 8 A 15 A 30 A 50 A
Display 2.8" TFT full colour 2.8" TFT full colour 2.8" TFT full colour 2.8" TFT full colour
Feeding 220V 50/60 Hz 220 V 50/60 Hz 220 V 50/60 Hz 220 V 50/60 Hz
Electronic box Black ABS flame retardant plastic Black ABS flame retardant plastic Black ABS flame retardant plastic Black ABS flame retardant plastic
Protective cover Yellow ABS plastic Yellow ABS plastic Yellow ABS plastic Yellow ABS plastic
Control 32-bit microprocessor 32-bit microprocessor 32-bit microprocessor 32-bit microprocessor
Dimming Amperage+Voltage Amperage+Voltage Amperage+Voltage Amperage+Voltage
Ventilation Forced Forced Forced Forced
Self-cleaning Programmable from 1 to 24 hours Programmable from 1 to 24 hours Programmable from 1 to 24 hours Programmable from 1 to 24 hours
Flow control Gas sensor Gas sensor Gas sensor Gas sensor
Production control g/L g/L g/L g/L
Alarms Low salinity / Lack of flow / pH / Memory error Low salinity / Lack of flow / pH / Memory error Low salinity / Lack of flow / pH / Memory error Low salinity / Lack of flow / pH / Memory error
Salinity test Detects gr/l of salt Detects gr/l of salt Detects gr/l of salt Detects gr/l of salt
Communications MODBUS / WIFI MODBUS / WIFI MODBUS / WIFI MODBUS / WIFI
Main control outputs Filtration / lighting / heating control Filtration / lighting / heating control Filtration / lighting / heating control Filtration / lighting / heating control
Additional control outputs 4 additional relay outputs 4 additional relay outputs 4 additional relay outputs 4 additional relay outputs