{"title":"Spare parts Hanna PCA","description":"\u003cp\u003eAutomatic control panels are among the highest-performance automatic control and regulation systems on the market. Ideal for public swimming pools, they monitor and dose disinfection products. In this section you will find spare parts for the HANNA PCA.\u003c\/p\u003e\n\u003cp\u003eProper maintenance means peak performance. Replace worn parts and extend the service life of your \u003cstrong\u003ePCA automatic control panel\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eThe PCA automatic control panel continuously analyses and doses free chlorine using a high-precision colorimetric method with DPD reagents.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThe most common spare parts are:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e     - Electrodes\u003cbr\u003e     - Reagents\u003cbr\u003e     - Tubing set\u003c\/p\u003e\n\u003cp\u003eAnd remember, if you cannot find the spare part you are looking for, do not hesitate to \u003ca href=\"\/en\/pages\/contact\" rel=\"nofollow\"\u003econtact\u003c\/a\u003e us. Or, if you prefer, call us on 91 128 55 90.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e24-hour delivery on thousands of products.\u003c\/strong\u003e What is more, you will now know exactly when each product will arrive. Order and receive it at your address in record time.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHanna E-Partner.\u003c\/strong\u003e QUIMIPOOL only sells genuine Hanna spare parts with the manufacturer's official warranty.\u003c\/p\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003c\/p\u003e","products":[{"product_id":"kit-reactivos-cloro-libre-para-hanna-pca","title":"Free chlorine reagent kit for Hanna PCA HI70430","description":"\u003cp\u003eThe analyser measures chlorine by the DPD method: in each measurement it adds reagent to the sample. With 5-minute sampling, the reagent needs replenishing roughly once a month. The unit warns with \"Low reagent\" when about 20% is left and with \"Reagent expired\" when the reagent is more than 3 months old.\u003c\/p\u003e\u003ch2\u003eSpare part details\u003c\/h2\u003e\u003cul\u003e\u003cli\u003e\u003cstrong\u003eManufacturer's description\u003c\/strong\u003e: Free chlorine reagent kit for PCA (0 to 5 mg\/L)\u003c\/li\u003e\u003cli\u003e\u003cstrong\u003eManufacturer code\u003c\/strong\u003e: HI70430\u003c\/li\u003e\u003cli\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e: Hanna Instruments\u003c\/li\u003e\u003cli\u003eRange: 0 to 5 mg\/L\u003c\/li\u003e\u003cli\u003eFormat: liquid reagent, 500 mL bottle\u003c\/li\u003e\u003c\/ul\u003e\u003ch2\u003eCompatible equipment\u003c\/h2\u003e\u003cp\u003eHanna lists this part among the accessories in the manual for the PCA series chlorine analysers:\u003c\/p\u003e\u003cul\u003e\u003cli\u003e\u003cstrong\u003eHanna PCA310\u003c\/strong\u003e: chlorine\u003c\/li\u003e\u003cli\u003e\u003cstrong\u003eHanna PCA320\u003c\/strong\u003e: chlorine, pH and temperature\u003c\/li\u003e\u003cli\u003e\u003cstrong\u003eHanna PCA330\u003c\/strong\u003e: chlorine, pH, temperature and ORP\u003c\/li\u003e\u003cli\u003e\u003cstrong\u003eHanna PCA340\u003c\/strong\u003e: chlorine, pH and temperature, with two analogue outputs\u003c\/li\u003e\u003c\/ul\u003e\u003cp\u003eFor analysers set up for \u003cstrong\u003efree chlorine\u003c\/strong\u003e. If your unit measures total chlorine, the kit is HI70431.\u003c\/p\u003e\u003ch2\u003eHow to identify your model\u003c\/h2\u003e\u003cp\u003eWhen switched on, the analyser shows on screen whether it is set up for \u003cstrong\u003eFree chlorine\u003c\/strong\u003e or \u003cstrong\u003eTotal chlorine\u003c\/strong\u003e. Use the kit that matches that setting. If in doubt, send us a photo of the display or of the unit's label before ordering and we will confirm it.\u003c\/p\u003e\u003ch2\u003eReplacement\u003c\/h2\u003e\u003col\u003e\u003cli\u003eWear rubber gloves and eye protection.\u003c\/li\u003e\u003cli\u003eReplace the reagent bottle.\u003c\/li\u003e\u003cli\u003eReset the reagent counter from the chlorine menu (change reagent, reset counter), or prime the circuit from the same menu, which also resets the counter. Otherwise the unit will keep warning of low or expired reagent.\u003c\/li\u003e\u003cli\u003eHanna recommends changing the peristaltic pump tubes at the same time.\u003c\/li\u003e\u003c\/ol\u003e","brand":"Hanna","offers":[{"title":"Default Title","offer_id":54378587881819,"sku":"01ESHI70430","price":75.9,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0990\/9600\/2907\/files\/8211.jpg?v=1792148257"},{"product_id":"recambio-hanna-pca-celula-de-medida","title":"Hanna PCA spare part Measuring cell HI704871","description":"\u003cp\u003eThe measuring cell is where the analyser mixes the sample with the reagents and reads the chlorine colorimetrically. If it is broken, or the blank calibration fails with the connection correct, it must be replaced.\u003c\/p\u003e\u003cp\u003eFirst rule out dirt: the \"Dirty cell\" warning is cleared by cleaning it. Hanna recommends cleaning it monthly with dilute acid and a cotton bud, and also every time the unit is switched off.\u003c\/p\u003e\u003ch2\u003eSpare part details\u003c\/h2\u003e\u003cul\u003e\u003cli\u003e\u003cstrong\u003eManufacturer's description\u003c\/strong\u003e: Measuring cell for PCA v.2\u003c\/li\u003e\u003cli\u003e\u003cstrong\u003eManufacturer code\u003c\/strong\u003e: HI704871\u003c\/li\u003e\u003cli\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e: Hanna Instruments\u003c\/li\u003e\u003c\/ul\u003e\u003cp\u003eHanna also sells reference SPPCA310-99, \"Measuring cell for PCA310\". If your unit is an older one, send us the serial number before ordering so we can confirm which one you need.\u003c\/p\u003e\u003ch2\u003eCompatible equipment\u003c\/h2\u003e\u003cp\u003eHanna lists this part among the accessories in the manual for the PCA series chlorine analysers:\u003c\/p\u003e\u003cul\u003e\u003cli\u003e\u003cstrong\u003eHanna PCA310\u003c\/strong\u003e: chlorine\u003c\/li\u003e\u003cli\u003e\u003cstrong\u003eHanna PCA320\u003c\/strong\u003e: chlorine, pH and temperature\u003c\/li\u003e\u003cli\u003e\u003cstrong\u003eHanna PCA330\u003c\/strong\u003e: chlorine, pH, temperature and ORP\u003c\/li\u003e\u003cli\u003e\u003cstrong\u003eHanna PCA340\u003c\/strong\u003e: chlorine, pH and temperature, with two analogue outputs\u003c\/li\u003e\u003c\/ul\u003e\u003ch2\u003eHow to identify your model\u003c\/h2\u003e\u003cp\u003eThe model is shown in the analyser's order code, PCA3a0-b: the digit \"a\" is the model (1 = PCA310, 2 = PCA320, 3 = PCA330, 4 = PCA340) and \"b\" the voltage (1 = 115 V, 2 = 230 V). If in doubt, send us a photo of the unit's label before ordering and we will confirm it.\u003c\/p\u003e\u003ch2\u003eReplacement\u003c\/h2\u003e\u003col\u003e\u003cli\u003eSwitch off the analyser at the main switch.\u003c\/li\u003e\u003cli\u003eRemove the buffer and reagent bottles to make room.\u003c\/li\u003e\u003cli\u003eDisconnect from the cell the reagent and buffer tubes, the sample inlet tube (the one coming from the solenoid valve) and the drain tube.\u003c\/li\u003e\u003cli\u003eDisconnect the cell's electrical connector and unscrew the cell from its holder with a hex key.\u003c\/li\u003e\u003cli\u003eFit the new cell, routing the electrical cable first, screw it in and reconnect the cable and tubes as they were.\u003c\/li\u003e\u003cli\u003eSwitch on the analyser and run the blank calibration from the chlorine menu (measuring cell calibration). If it shows \"fail\", check the cable connection.\u003c\/li\u003e\u003cli\u003ePrime the reagent pump, wait 3 cycles for the reading to stabilise and calibrate the cell.\u003c\/li\u003e\u003cli\u003eBefore measuring, check that the stirring bar (HI70486) is inside the cell.\u003c\/li\u003e\u003c\/ol\u003e","brand":"Hanna","offers":[{"title":"Default Title","offer_id":54378781442395,"sku":"13RPHI70487N","price":459.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0990\/9600\/2907\/files\/23874.jpg?v=1792149933"},{"product_id":"recambio-hanna-pca-imn-agitador-para-cmara-de-medida-del-clorador-2-unidades","title":"Hanna PCA spare part Stirring bar for chlorine measuring cell (2 units) HI70486","description":"\u003cp\u003eThe stirring bar (magnet) mixes the reagents with the sample inside the measuring cell; it is driven by a magnetically coupled stirrer. Without proper stirring, the reagent is not spread evenly and the chlorine reading fails.\u003c\/p\u003e\u003ch2\u003eSpare part details\u003c\/h2\u003e\u003cul\u003e\u003cli\u003e\u003cstrong\u003eManufacturer's description\u003c\/strong\u003e: Stirring magnet for PCA chlorine measuring chamber (2 pcs)\u003c\/li\u003e\u003cli\u003e\u003cstrong\u003eManufacturer code\u003c\/strong\u003e: HI70486\u003c\/li\u003e\u003cli\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e: Hanna Instruments\u003c\/li\u003e\u003cli\u003eContents: 2 units\u003c\/li\u003e\u003c\/ul\u003e\u003ch2\u003eCompatible equipment\u003c\/h2\u003e\u003cp\u003eHanna lists this part among the accessories in the manual for the PCA series chlorine analysers:\u003c\/p\u003e\u003cul\u003e\u003cli\u003e\u003cstrong\u003eHanna PCA310\u003c\/strong\u003e: chlorine\u003c\/li\u003e\u003cli\u003e\u003cstrong\u003eHanna PCA320\u003c\/strong\u003e: chlorine, pH and temperature\u003c\/li\u003e\u003cli\u003e\u003cstrong\u003eHanna PCA330\u003c\/strong\u003e: chlorine, pH, temperature and ORP\u003c\/li\u003e\u003cli\u003e\u003cstrong\u003eHanna PCA340\u003c\/strong\u003e: chlorine, pH and temperature, with two analogue outputs\u003c\/li\u003e\u003c\/ul\u003e\u003ch2\u003eHow to identify your model\u003c\/h2\u003e\u003cp\u003eThe model is shown in the analyser's order code, PCA3a0-b: the digit \"a\" is the model (1 = PCA310, 2 = PCA320, 3 = PCA330, 4 = PCA340) and \"b\" the voltage (1 = 115 V, 2 = 230 V). If in doubt, send us a photo of the unit's label before ordering and we will confirm it.\u003c\/p\u003e\u003ch2\u003eReplacement\u003c\/h2\u003e\u003col\u003e\u003cli\u003eSwitch off the analyser before handling the measuring cell.\u003c\/li\u003e\u003cli\u003eBefore measuring again, check that the stirring bar is inside the cell: Hanna's manual expressly asks for this.\u003c\/li\u003e\u003cli\u003eHanna has a video on its support channel showing how to check the PCA's stirring.\u003c\/li\u003e\u003c\/ol\u003e","brand":"Hanna","offers":[{"title":"Default Title","offer_id":54378781507931,"sku":"13RPHI70486","price":53.32,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0990\/9600\/2907\/files\/18876.jpg?v=1792149934"},{"product_id":"recambio-hanna-pca-electrodo-amplificado-de-ph","title":"Hanna PCA spare part Amplified pH electrode HI1005","description":"\u003cp\u003eThe pH probe measures the pH and temperature of the sample so the analyser can dose the pH corrector. It must be replaced if the shaft or membrane is cracked or if it does not respond to pH changes. First check that the cable is undamaged and try the cleaning described in the manual.\u003c\/p\u003e\u003ch2\u003eSpare part details\u003c\/h2\u003e\u003cul\u003e\u003cli\u003e\u003cstrong\u003eManufacturer's description\u003c\/strong\u003e: Amplified pH electrode, plastic body, temp. sensor, PTFE junction, 6 bar, 0.5 m, DIN connector, for PCA 320\/330\u003c\/li\u003e\u003cli\u003e\u003cstrong\u003eManufacturer code\u003c\/strong\u003e: HI1005\u003c\/li\u003e\u003cli\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e: Hanna Instruments\u003c\/li\u003e\u003cli\u003eRange: pH 0 to 14\u003c\/li\u003e\u003cli\u003eTemperature sensor: Pt100\u003c\/li\u003e\u003cli\u003eJunction: double, PTFE\u003c\/li\u003e\u003cli\u003eElectrolyte: polymer\u003c\/li\u003e\u003cli\u003eMaximum pressure: 6 bar\u003c\/li\u003e\u003cli\u003eCable: 0.5 m with DIN connector\u003c\/li\u003e\u003c\/ul\u003e\u003ch2\u003eCompatible equipment\u003c\/h2\u003e\u003cp\u003eAccording to Hanna's manual, the \u003cstrong\u003ePCA320, PCA330 and PCA340\u003c\/strong\u003e analysers use this probe. The PCA310 does not measure pH.\u003c\/p\u003e\u003ch2\u003eHow to identify your model\u003c\/h2\u003e\u003cp\u003eThe model is shown in the analyser's order code, PCA3a0-b: the digit \"a\" is the model (1 = PCA310, 2 = PCA320, 3 = PCA330, 4 = PCA340) and \"b\" the voltage (1 = 115 V, 2 = 230 V). If in doubt, send us a photo of the unit's label before ordering and we will confirm it.\u003c\/p\u003e\u003ch2\u003eReplacement\u003c\/h2\u003e\u003col\u003e\u003cli\u003eSwitch off the analyser: never connect or disconnect the probes with the analyser switched on.\u003c\/li\u003e\u003cli\u003eRemove the protective cap. If the membrane or junction is dry, soak the probe for at least one hour in HI70300 storage solution.\u003c\/li\u003e\u003cli\u003eScrew it into the lower position of the electrode holder and check there are no leaks.\u003c\/li\u003e\u003cli\u003eWith the probe in its final position, plug it into its connector and secure it with the built-in nut.\u003c\/li\u003e\u003cli\u003eCalibrate the pH from the pH menu (pH probe calibration). Hanna recommends calibrating every time the probe is replaced.\u003c\/li\u003e\u003c\/ol\u003e\u003cp\u003eTo keep the membrane from drying out, the installation must keep the probe holder full of sample.\u003c\/p\u003e","brand":"Hanna","offers":[{"title":"Default Title","offer_id":54378781606235,"sku":"13RPHI1005","price":225.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0990\/9600\/2907\/files\/18874.jpg?v=1792149936"},{"product_id":"recambio-hanna-pca-set-completo-de-tubos-3-unidades","title":"Hanna PCA spare part Complete tubing kit (3 units) HI70484","description":"\u003cp\u003eThe tubes carry the sample and the reagents inside the analyser. With use they fatigue, crack or lose elasticity, causing leaks or uneven reagent dosing. Hanna recommends changing the peristaltic pump tubes every month with 5-minute continuous sampling (better still, every time the reagents are replenished) and the rest of the analyser's tubes every two months.\u003c\/p\u003e\u003cp\u003eThis pack contains three complete kits, for three changes.\u003c\/p\u003e\u003ch2\u003eSpare part details\u003c\/h2\u003e\u003cul\u003e\u003cli\u003e\u003cstrong\u003eManufacturer's description\u003c\/strong\u003e: Complete tubing kit for PCA (3 pcs)\u003c\/li\u003e\u003cli\u003e\u003cstrong\u003eManufacturer code\u003c\/strong\u003e: HI70484\u003c\/li\u003e\u003cli\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e: Hanna Instruments\u003c\/li\u003e\u003c\/ul\u003e\u003cp\u003eFor a single change, the reference is HI70483 (single kit).\u003c\/p\u003e\u003ch2\u003eCompatible equipment\u003c\/h2\u003e\u003cp\u003eHanna lists this part among the accessories in the manual for the PCA series chlorine analysers:\u003c\/p\u003e\u003cul\u003e\u003cli\u003e\u003cstrong\u003eHanna PCA310\u003c\/strong\u003e: chlorine\u003c\/li\u003e\u003cli\u003e\u003cstrong\u003eHanna PCA320\u003c\/strong\u003e: chlorine, pH and temperature\u003c\/li\u003e\u003cli\u003e\u003cstrong\u003eHanna PCA330\u003c\/strong\u003e: chlorine, pH, temperature and ORP\u003c\/li\u003e\u003cli\u003e\u003cstrong\u003eHanna PCA340\u003c\/strong\u003e: chlorine, pH and temperature, with two analogue outputs\u003c\/li\u003e\u003c\/ul\u003e\u003ch2\u003eHow to identify your model\u003c\/h2\u003e\u003cp\u003eThe model is shown in the analyser's order code, PCA3a0-b: the digit \"a\" is the model (1 = PCA310, 2 = PCA320, 3 = PCA330, 4 = PCA340) and \"b\" the voltage (1 = 115 V, 2 = 230 V). If in doubt, send us a photo of the unit's label before ordering and we will confirm it.\u003c\/p\u003e\u003ch2\u003eReplacement\u003c\/h2\u003e\u003col\u003e\u003cli\u003eWear rubber gloves and eye protection: the reagent tubes may contain chemical residue.\u003c\/li\u003e\u003cli\u003ePump tubes: hold the plastic collar of one tube and pull the connector towards the front of the housing until the retaining notch is released. Then move the connectors sideways until the tube comes out of the slot.\u003c\/li\u003e\u003cli\u003eRemove the reagent tubes from the connector, pull the tube out from behind the rollers and fit the new one in reverse order. Repeat with the second pump tube.\u003c\/li\u003e\u003cli\u003eOther tubes: change them one at a time so as not to mix up the connections. Dipping the new tubes in hot water makes them easier to fit.\u003c\/li\u003e\u003c\/ol\u003e\u003cp\u003eThe DPD reagent tubes may darken before they are due for replacement; according to Hanna, this does not affect the measurement.\u003c\/p\u003e","brand":"Hanna","offers":[{"title":"Default Title","offer_id":54378781704539,"sku":"13RPHI70484","price":329.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0990\/9600\/2907\/files\/23527.jpg?v=1792149938"},{"product_id":"recambio-hanna-pca-set-completo-de-tubos","title":"Hanna PCA spare part Complete tubing kit HI70483","description":"\u003cp\u003eThe tubes carry the sample and the reagents inside the analyser. With use they fatigue, crack or lose elasticity, causing leaks or uneven reagent dosing. Hanna recommends changing the peristaltic pump tubes every month with 5-minute continuous sampling (better still, every time the reagents are replenished) and the rest of the analyser's tubes every two months.\u003c\/p\u003e\u003ch2\u003eSpare part details\u003c\/h2\u003e\u003cul\u003e\u003cli\u003e\u003cstrong\u003eManufacturer's description\u003c\/strong\u003e: Complete tubing kit for PCA\u003c\/li\u003e\u003cli\u003e\u003cstrong\u003eManufacturer code\u003c\/strong\u003e: HI70483\u003c\/li\u003e\u003cli\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e: Hanna Instruments\u003c\/li\u003e\u003c\/ul\u003e\u003cp\u003eHanna also offers this kit in a pack of 3 (reference HI70484).\u003c\/p\u003e\u003ch2\u003eCompatible equipment\u003c\/h2\u003e\u003cp\u003eHanna lists this part among the accessories in the manual for the PCA series chlorine analysers:\u003c\/p\u003e\u003cul\u003e\u003cli\u003e\u003cstrong\u003eHanna PCA310\u003c\/strong\u003e: chlorine\u003c\/li\u003e\u003cli\u003e\u003cstrong\u003eHanna PCA320\u003c\/strong\u003e: chlorine, pH and temperature\u003c\/li\u003e\u003cli\u003e\u003cstrong\u003eHanna PCA330\u003c\/strong\u003e: chlorine, pH, temperature and ORP\u003c\/li\u003e\u003cli\u003e\u003cstrong\u003eHanna PCA340\u003c\/strong\u003e: chlorine, pH and temperature, with two analogue outputs\u003c\/li\u003e\u003c\/ul\u003e\u003ch2\u003eHow to identify your model\u003c\/h2\u003e\u003cp\u003eThe model is shown in the analyser's order code, PCA3a0-b: the digit \"a\" is the model (1 = PCA310, 2 = PCA320, 3 = PCA330, 4 = PCA340) and \"b\" the voltage (1 = 115 V, 2 = 230 V). If in doubt, send us a photo of the unit's label before ordering and we will confirm it.\u003c\/p\u003e\u003ch2\u003eReplacement\u003c\/h2\u003e\u003col\u003e\u003cli\u003eWear rubber gloves and eye protection: the reagent tubes may contain chemical residue.\u003c\/li\u003e\u003cli\u003ePump tubes: hold the plastic collar of one tube and pull the connector towards the front of the housing until the retaining notch is released. Then move the connectors sideways until the tube comes out of the slot.\u003c\/li\u003e\u003cli\u003eRemove the reagent tubes from the connector, pull the tube out from behind the rollers and fit the new one in reverse order. Repeat with the second pump tube.\u003c\/li\u003e\u003cli\u003eOther tubes: change them one at a time so as not to mix up the connections. Dipping the new tubes in hot water makes them easier to fit.\u003c\/li\u003e\u003c\/ol\u003e\u003cp\u003eThe DPD reagent tubes may darken before they are due for replacement; according to Hanna, this does not affect the measurement.\u003c\/p\u003e","brand":"Hanna","offers":[{"title":"Default Title","offer_id":54378781835611,"sku":"13RPHI70483","price":115.22,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0990\/9600\/2907\/files\/18872.jpg?v=1792149940"},{"product_id":"recambio-hanna-pca-electrovalvula-24-vac-50-hz","title":"Hanna PCA spare part Solenoid valve 24 VAC \/ 50 Hz HI70489","description":"\u003cp\u003eThe solenoid valve opens and closes the sample inlet to the cell in every measuring cycle: it stays open to renew the sample and closes to measure. If it sticks open or closed, the analyser cannot measure properly.\u003c\/p\u003e\u003cp\u003eBefore replacing it, check the filter: according to Hanna, a very thin flow when it opens means the filter is clogged. It is reached by removing the inlet fitting.\u003c\/p\u003e\u003ch2\u003eSpare part details\u003c\/h2\u003e\u003cul\u003e\u003cli\u003e\u003cstrong\u003eManufacturer's description\u003c\/strong\u003e: Solenoid valve for PCA, 24VAC\/50HZ\u003c\/li\u003e\u003cli\u003e\u003cstrong\u003eManufacturer code\u003c\/strong\u003e: HI70489\u003c\/li\u003e\u003cli\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e: Hanna Instruments\u003c\/li\u003e\u003cli\u003ePower supply: 24 V AC, 50 Hz\u003c\/li\u003e\u003c\/ul\u003e\u003cp\u003eCheck your mains frequency: for 60 Hz, Hanna offers version HI70488.\u003c\/p\u003e\u003ch2\u003eCompatible equipment\u003c\/h2\u003e\u003cp\u003eHanna lists this part among the accessories in the manual for the PCA series chlorine analysers:\u003c\/p\u003e\u003cul\u003e\u003cli\u003e\u003cstrong\u003eHanna PCA310\u003c\/strong\u003e: chlorine\u003c\/li\u003e\u003cli\u003e\u003cstrong\u003eHanna PCA320\u003c\/strong\u003e: chlorine, pH and temperature\u003c\/li\u003e\u003cli\u003e\u003cstrong\u003eHanna PCA330\u003c\/strong\u003e: chlorine, pH, temperature and ORP\u003c\/li\u003e\u003cli\u003e\u003cstrong\u003eHanna PCA340\u003c\/strong\u003e: chlorine, pH and temperature, with two analogue outputs\u003c\/li\u003e\u003c\/ul\u003e\u003ch2\u003eHow to identify your model\u003c\/h2\u003e\u003cp\u003eThe model is shown in the analyser's order code, PCA3a0-b: the digit \"a\" is the model (1 = PCA310, 2 = PCA320, 3 = PCA330, 4 = PCA340) and \"b\" the voltage (1 = 115 V, 2 = 230 V). If in doubt, send us a photo of the unit's label before ordering and we will confirm it.\u003c\/p\u003e\u003ch2\u003eReplacement\u003c\/h2\u003e\u003col\u003e\u003cli\u003eSwitch off the analyser and shut off the sample inlet before handling it.\u003c\/li\u003e\u003cli\u003eThe solenoid valve is item no. 21 in the manual's diagram: the sample enters through a nylon tube and the outlet goes to the drain port and the measuring cell. Fit the new one keeping those connections.\u003c\/li\u003e\u003cli\u003eWhen finished, check that the valve opens and closes correctly.\u003c\/li\u003e\u003c\/ol\u003e\u003cp\u003eHanna's manual does not describe how to remove the solenoid valve; if in doubt, ask us before you start.\u003c\/p\u003e","brand":"Hanna","offers":[{"title":"Default Title","offer_id":54378781901147,"sku":"13RPHI70489","price":219.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0990\/9600\/2907\/files\/18873.jpg?v=1792149941"},{"product_id":"recambio-hanna-pca-electrodo-amplificado-de-orp","title":"Hanna PCA spare part Amplified ORP electrode HI2008","description":"\u003cp\u003eThe redox probe measures the oxidation-reduction potential (ORP) of the sample. Before replacing it, try cleaning it: Hanna's manual says to polish the metal tip with slightly abrasive paper, without scratching it, and rinse it well with water.\u003c\/p\u003e\u003ch2\u003eSpare part details\u003c\/h2\u003e\u003cul\u003e\u003cli\u003e\u003cstrong\u003eManufacturer's description\u003c\/strong\u003e: Amplified ORP electrode, plastic body, PTFE junction, 6 bar, 0.5 m, DIN connector, for PCA330\u003c\/li\u003e\u003cli\u003e\u003cstrong\u003eManufacturer code\u003c\/strong\u003e: HI2008\u003c\/li\u003e\u003cli\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e: Hanna Instruments\u003c\/li\u003e\u003cli\u003eJunction: double, PTFE\u003c\/li\u003e\u003cli\u003eElectrolyte: polymer\u003c\/li\u003e\u003cli\u003eMaximum pressure: 6 bar\u003c\/li\u003e\u003cli\u003eCable: 0.5 m with DIN connector\u003c\/li\u003e\u003c\/ul\u003e\u003ch2\u003eCompatible equipment\u003c\/h2\u003e\u003cp\u003eAccording to Hanna's manual, the \u003cstrong\u003ePCA330\u003c\/strong\u003e is the model in the series that measures ORP and uses this probe.\u003c\/p\u003e\u003ch2\u003eHow to identify your model\u003c\/h2\u003e\u003cp\u003eThe model is shown in the analyser's order code, PCA3a0-b: the digit \"a\" is the model (1 = PCA310, 2 = PCA320, 3 = PCA330, 4 = PCA340) and \"b\" the voltage (1 = 115 V, 2 = 230 V). If in doubt, send us a photo of the unit's label before ordering and we will confirm it.\u003c\/p\u003e\u003ch2\u003eReplacement\u003c\/h2\u003e\u003col\u003e\u003cli\u003eSwitch off the analyser: never connect or disconnect the probes with the analyser switched on.\u003c\/li\u003e\u003cli\u003eRemove the protective cap and screw the probe into the upper position of the electrode holder. Check there are no leaks.\u003c\/li\u003e\u003cli\u003eWith the probe in its final position, plug it into its connector and secure it with the built-in nut.\u003c\/li\u003e\u003c\/ol\u003e","brand":"Hanna","offers":[{"title":"Default Title","offer_id":54378781966683,"sku":"13RPHI2008","price":279.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0990\/9600\/2907\/files\/18875.jpg?v=1792149942"},{"product_id":"kit-reactivos-cloro-total-para-hanna-pca","title":"Total chlorine reagent kit for Hanna PCA HI70431","description":"\u003cp\u003eThe analyser measures chlorine by the DPD method: in each measurement it adds reagent to the sample. With 5-minute sampling, the reagent needs replenishing roughly once a month. The unit warns with \"Low reagent\" when about 20% is left and with \"Reagent expired\" when the reagent is more than 3 months old.\u003c\/p\u003e\u003ch2\u003eSpare part details\u003c\/h2\u003e\u003cul\u003e\u003cli\u003e\u003cstrong\u003eManufacturer's description\u003c\/strong\u003e: Total chlorine reagent kit for PCA (0 to 5 mg\/L)\u003c\/li\u003e\u003cli\u003e\u003cstrong\u003eManufacturer code\u003c\/strong\u003e: HI70431\u003c\/li\u003e\u003cli\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e: Hanna Instruments\u003c\/li\u003e\u003cli\u003eRange: 0 to 5 mg\/L\u003c\/li\u003e\u003cli\u003eFormat: liquid reagent, 500 mL bottle\u003c\/li\u003e\u003c\/ul\u003e\u003ch2\u003eCompatible equipment\u003c\/h2\u003e\u003cp\u003eHanna lists this part among the accessories in the manual for the PCA series chlorine analysers:\u003c\/p\u003e\u003cul\u003e\u003cli\u003e\u003cstrong\u003eHanna PCA310\u003c\/strong\u003e: chlorine\u003c\/li\u003e\u003cli\u003e\u003cstrong\u003eHanna PCA320\u003c\/strong\u003e: chlorine, pH and temperature\u003c\/li\u003e\u003cli\u003e\u003cstrong\u003eHanna PCA330\u003c\/strong\u003e: chlorine, pH, temperature and ORP\u003c\/li\u003e\u003cli\u003e\u003cstrong\u003eHanna PCA340\u003c\/strong\u003e: chlorine, pH and temperature, with two analogue outputs\u003c\/li\u003e\u003c\/ul\u003e\u003cp\u003eFor analysers set up for \u003cstrong\u003etotal chlorine\u003c\/strong\u003e. If your unit measures free chlorine, the kit is HI70430.\u003c\/p\u003e\u003ch2\u003eHow to identify your model\u003c\/h2\u003e\u003cp\u003eWhen switched on, the analyser shows on screen whether it is set up for \u003cstrong\u003eFree chlorine\u003c\/strong\u003e or \u003cstrong\u003eTotal chlorine\u003c\/strong\u003e. Use the kit that matches that setting. If in doubt, send us a photo of the display or of the unit's label before ordering and we will confirm it.\u003c\/p\u003e\u003ch2\u003eReplacement\u003c\/h2\u003e\u003col\u003e\u003cli\u003eWear rubber gloves and eye protection.\u003c\/li\u003e\u003cli\u003eReplace the reagent bottle.\u003c\/li\u003e\u003cli\u003eReset the reagent counter from the chlorine menu (change reagent, reset counter), or prime the circuit from the same menu, which also resets the counter. Otherwise the unit will keep warning of low or expired reagent.\u003c\/li\u003e\u003cli\u003eHanna recommends changing the peristaltic pump tubes at the same time.\u003c\/li\u003e\u003c\/ol\u003e","brand":"Hanna","offers":[{"title":"Default Title","offer_id":54378782032219,"sku":"01ESHI70431","price":75.9,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0990\/9600\/2907\/files\/14386.jpg?v=1792149944"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0990\/9600\/2907\/collections\/819.jpg?v=1792140045","url":"https:\/\/www.quimipool.com\/en\/collections\/spare-parts-hanna-pca.oembed","provider":"Quimipool","version":"1.0","type":"link"}