{"title":"Spare parts CTX e-Series pH","description":"\u003cp\u003e\u003cbr \/\u003e\u003cbr \/\u003e\u003c\/p\u003e\r\n\u003ch2\u003eReplacement Parts for the CTX, and e-Series pH Pumps: Probe, Peristaltic Tube, and Calibration\u003c\/h2\u003e\r\n\u003cp\u003eThe \u003cstrong\u003ee-Series pH\u003c\/strong\u003e from \u003cstrong\u003eCTX\u003c\/strong\u003e is one of the most widely installed pH control pumps in residential pools: peristaltic, compact, and featuring a pH probe integrated into the circuit. Maintenance is limited to \u003cstrong\u003etwo consumables and a routine procedure\u003c\/strong\u003e: the \u003cstrong\u003eperistaltic tube\u003c\/strong\u003e, the \u003cstrong\u003epH probe\u003c\/strong\u003e, and \u003cstrong\u003eperiodic calibration\u003c\/strong\u003e to ensure the equipment operates reliably.\u003c\/p\u003e\r\n\u003cp\u003eOn this page, you’ll find \u003cstrong\u003ereplacement parts with prices\u003c\/strong\u003e — probes, Santoprene tubing, roller holders, probe holders, collars, and calibration solution — as well as a \u003cstrong\u003esetup guide\u003c\/strong\u003e that answers the most common questions about use: how to calibrate, how often, and what to do when the pH reading on the display doesn’t match that of the analyzer.\u003c\/p\u003e\r\n\u003cp\u003eA useful technical note: the e-Series is built on the \u003cstrong\u003eSeko\u003c\/strong\u003e, so its head replacement parts (tube and roller holders) are the same as those for that series.\u003c\/p\u003e\r\n\u003cp\u003e\u003cstrong\u003eRelated categories:\u003c\/strong\u003e \u003ca href=\"\/en\/collections\/spare-parts-metering-pumps\"\u003eDosage pump replacement parts\u003c\/a\u003e · \u003ca href=\"\/en\/collections\/automatic-ph-control\"\u003eAutomatic pH control\u003c\/a\u003e · \u003ca href=\"\/en\/collections\/metering-pumps\"\u003eDosage pumps\u003c\/a\u003e · \u003ca href=\"\/en\/collections\/dosing-accessories\"\u003eDosage accessories\u003c\/a\u003e · \u003ca href=\"\/en\/collections\/swimming-pool-water-analysis\"\u003eWater analysis\u003c\/a\u003e · \u003ca href=\"\/en\/collections\/technical-service\"\u003eTechnical service\u003c\/a\u003e\u003c\/p\u003e\r\n\u003ch2\u003eThe pH probe: the most sought-after replacement part\u003c\/h2\u003e\r\n\u003cp\u003eThe probe (or electrode) is \u003cstrong\u003ethe component that determines whether your pool is properly treated\u003c\/strong\u003e. When it wears out, the system continues to operate but provides inaccurate readings—and doses acid based on incorrect data. Typical service life: \u003cstrong\u003e2–3 seasons\u003c\/strong\u003e.\u003c\/p\u003e\r\n\u003ctable style=\"width: 100%; border-collapse: collapse; margin: 15px 0 30px 0; border: 1px solid #d6dde1;\"\u003e\r\n\u003cthead style=\"border: 1px solid #d6dde1; background-color: #f2f6f7; padding: 10px 12px; text-align: left; vertical-align: top;\"\u003e\r\n\u003ctr class=\"header\"\u003e\r\n\u003cth style=\"border: 1px solid #d6dde1; background-color: #f2f6f7; padding: 10px 12px; text-align: left; vertical-align: top;\"\u003eProbe\u003c\/th\u003e\r\n\u003cth style=\"border: 1px solid #d6dde1; background-color: #f2f6f7; padding: 10px 12px; text-align: left; vertical-align: top;\"\u003eApproximate price\u003c\/th\u003e\r\n\u003cth style=\"border: 1px solid #d6dde1; background-color: #f2f6f7; padding: 10px 12px; text-align: left; vertical-align: top;\"\u003eNotes\u003c\/th\u003e\r\n\u003c\/tr\u003e\r\n\u003c\/thead\u003e\r\n\u003ctbody\u003e\r\n\u003ctr class=\"odd\"\u003e\r\n\u003ctd style=\"border: 1px solid #d6dde1; padding: 10px 12px; vertical-align: top;\"\u003e\u003cstrong\u003e\u003ca href=\"\/en\/products\/15-metre-ph-electrode\"\u003e Seko pH Electrode, 1.5 m\u003c\/a\u003e\u003c\/strong\u003e\u003c\/td\u003e\r\n\u003ctd style=\"border: 1px solid #d6dde1; padding: 10px 12px; vertical-align: top;\"\u003e€74.90\u003c\/td\u003e\r\n\u003ctd style=\"border: 1px solid #d6dde1; padding: 10px 12px; vertical-align: top;\"\u003eSeko platform electrode with a 1.5-meter cable.\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr class=\"even\"\u003e\r\n\u003ctd style=\"border: 1px solid #d6dde1; padding: 10px 12px; vertical-align: top;\"\u003e\u003cstrong\u003e\u003ca href=\"\/en\/products\/2-metre-ph-electrode-hanna-hi2114p\"\u003e Hanna HI2114P pH Electrode (2 m)\u003c\/a\u003e\u003c\/strong\u003e\u003c\/td\u003e\r\n\u003ctd style=\"border: 1px solid #d6dde1; padding: 10px 12px; vertical-align: top;\"\u003e€76.90\u003c\/td\u003e\r\n\u003ctd style=\"border: 1px solid #d6dde1; padding: 10px 12px; vertical-align: top;\"\u003eVersion with \u003cstrong\u003ea 2-meter cable\u003c\/strong\u003e, useful when the distance between the probe holder and the instrument is greater.\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr class=\"odd\"\u003e\r\n\u003ctd style=\"border: 1px solid #d6dde1; padding: 10px 12px; vertical-align: top;\"\u003e\u003cstrong\u003e\u003ca href=\"\/en\/products\/ph-electrode-kit-astralpool\"\u003epH Electrode Kit Astralpool\u003c\/a\u003e\u003c\/strong\u003e\u003c\/td\u003e\r\n\u003ctd style=\"border: 1px solid #d6dde1; padding: 10px 12px; vertical-align: top;\"\u003e€79.90\u003c\/td\u003e\r\n\u003ctd style=\"border: 1px solid #d6dde1; padding: 10px 12px; vertical-align: top;\"\u003eComplete electrode kit.\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003c\/tbody\u003e\r\n\u003c\/table\u003e\r\n\u003cp\u003e \u003c\/p\u003e\r\n\u003cp\u003e\u003cstrong\u003eBefore ordering, measure the distance\u003c\/strong\u003e between the probe installation point and the equipment: this will determine whether the 1.5-meter cable is long enough or if you need the 2-meter one. Also, check the \u003cstrong\u003econnector type on\u003c\/strong\u003e your current probe.\u003c\/p\u003e\r\n\u003ch2\u003eHead, probe holder, and installation\u003c\/h2\u003e\r\n\u003ctable style=\"width: 100%; border-collapse: collapse; margin: 15px 0 30px 0; border: 1px solid #d6dde1;\"\u003e\r\n\u003cthead style=\"border: 1px solid #d6dde1; background-color: #f2f6f7; padding: 10px 12px; text-align: left; vertical-align: top;\"\u003e\r\n\u003ctr class=\"header\"\u003e\r\n\u003cth style=\"border: 1px solid #d6dde1; background-color: #f2f6f7; padding: 10px 12px; text-align: left; vertical-align: top;\"\u003eReplacement\u003c\/th\u003e\r\n\u003cth style=\"border: 1px solid #d6dde1; background-color: #f2f6f7; padding: 10px 12px; text-align: left; vertical-align: top;\"\u003eEstimated price\u003c\/th\u003e\r\n\u003cth style=\"border: 1px solid #d6dde1; background-color: #f2f6f7; padding: 10px 12px; text-align: left; vertical-align: top;\"\u003eWhat it’s used for\u003c\/th\u003e\r\n\u003c\/tr\u003e\r\n\u003c\/thead\u003e\r\n\u003ctbody\u003e\r\n\u003ctr class=\"odd\"\u003e\r\n\u003ctd style=\"border: 1px solid #d6dde1; padding: 10px 12px; vertical-align: top;\"\u003e\u003cstrong\u003e\u003ca href=\"\/en\/products\/santopreno-peristaltic-tube-6x10mm-connection-4x6\"\u003eSantoprene peristaltic tube (6x10 mm, 4x6 connection)\u003c\/a\u003e\u003c\/strong\u003e\u003c\/td\u003e\r\n\u003ctd style=\"border: 1px solid #d6dde1; padding: 10px 12px; vertical-align: top;\"\u003e€18.90\u003c\/td\u003e\r\n\u003ctd style=\"border: 1px solid #d6dde1; padding: 10px 12px; vertical-align: top;\"\u003e\u003cstrong\u003eThe No. 1 consumable.\u003c\/strong\u003e This is the tube that the rollers squeeze to pump fluid. It hardens when exposed to acid and loses flow capacity. Replace every 1–2 seasons.\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr class=\"even\"\u003e\r\n\u003ctd style=\"border: 1px solid #d6dde1; padding: 10px 12px; vertical-align: top;\"\u003e\u003cstrong\u003e\u003ca href=\"\/en\/products\/roller-cylinder-holder-pump-persitaltica-seko\"\u003eRoller holder\u003c\/a\u003e\u003c\/strong\u003e\u003c\/td\u003e\r\n\u003ctd style=\"border: 1px solid #d6dde1; padding: 10px 12px; vertical-align: top;\"\u003e€15.95\u003c\/td\u003e\r\n\u003ctd style=\"border: 1px solid #d6dde1; padding: 10px 12px; vertical-align: top;\"\u003eThe rotor assembly with the rollers that compress the tube. Replace if the rollers turn with difficulty or show signs of wear.\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr class=\"odd\"\u003e\r\n\u003ctd style=\"border: 1px solid #d6dde1; padding: 10px 12px; vertical-align: top;\"\u003e\u003cstrong\u003e\u003ca href=\"\/en\/products\/spare-part-seko-pss3-probe-holder-long\"\u003eLong PSS3 Probe Holder\u003c\/a\u003e\u003c\/strong\u003e\u003c\/td\u003e\r\n\u003ctd style=\"border: 1px solid #d6dde1; padding: 10px 12px; vertical-align: top;\"\u003e€23.95\u003c\/td\u003e\r\n\u003ctd style=\"border: 1px solid #d6dde1; padding: 10px 12px; vertical-align: top;\"\u003eThe housing where the probe is installed in the pipe. Replace if it is cracked or no longer seals properly.\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr class=\"even\"\u003e\r\n\u003ctd style=\"border: 1px solid #d6dde1; padding: 10px 12px; vertical-align: top;\"\u003e\u003cstrong\u003e\u003ca href=\"\/en\/products\/collar-for-pvc-pipe-50-1-2\"\u003eCollar for 50-1\/2” PVC pipe\u003c\/a\u003e\u003c\/strong\u003e\u003c\/td\u003e\r\n\u003ctd style=\"border: 1px solid #d6dde1; padding: 10px 12px; vertical-align: top;\"\u003e€2.59\u003c\/td\u003e\r\n\u003ctd style=\"border: 1px solid #d6dde1; padding: 10px 12px; vertical-align: top;\"\u003eThe connection collar for 50 mm pipe with a 1\/2” outlet.\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr class=\"odd\"\u003e\r\n\u003ctd style=\"border: 1px solid #d6dde1; padding: 10px 12px; vertical-align: top;\"\u003e\u003cstrong\u003e\u003ca href=\"\/en\/products\/buffer-solution-seko-ph7-50-ml\"\u003epH 7 buffer solution (50 ml)\u003c\/a\u003e\u003c\/strong\u003e\u003c\/td\u003e\r\n\u003ctd style=\"border: 1px solid #d6dde1; padding: 10px 12px; vertical-align: top;\"\u003e€5.99\u003c\/td\u003e\r\n\u003ctd style=\"border: 1px solid #d6dde1; padding: 10px 12px; vertical-align: top;\"\u003eThe calibration standard. \u003cstrong\u003eReplace it every season\u003c\/strong\u003e: an old solution calibrates poorly.\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003c\/tbody\u003e\r\n\u003c\/table\u003e\r\n\u003cp\u003e \u003c\/p\u003e\r\n\u003ch2\u003eCalibrating the e-Series pH: the ritual that keeps everything accurate\u003c\/h2\u003e\r\n\u003cp\u003eThis is the most common question about this device, so let’s get right to the point. \u003cstrong\u003eCalibration is about teaching the pump what a known pH value is\u003c\/strong\u003e so it can accurately interpret its measurements.\u003c\/p\u003e\r\n\u003cp\u003e\u003cstrong\u003eWhen to do it:\u003c\/strong\u003e\u003c\/p\u003e\r\n\u003cul\u003e\r\n\u003cli\u003e\u003cstrong\u003eAt the start of each season\u003c\/strong\u003e, always\u003c\/li\u003e\r\n\u003cli\u003e\u003cstrong\u003eEvery 2–3 months\u003c\/strong\u003e during the season\u003c\/li\u003e\r\n\u003cli\u003e\u003cstrong\u003eWhenever you replace the probe\u003c\/strong\u003e\u003c\/li\u003e\r\n\u003cli\u003e\u003cstrong\u003eWhen the pH reading on the display does not match\u003c\/strong\u003e that of your \u003ca href=\"\/en\/collections\/swimming-pool-water-analysis\"\u003ereference analyzer\u003c\/a\u003e\u003c\/li\u003e\r\n\u003c\/ul\u003e\r\n\u003cp\u003e\u003cstrong\u003eBasically:\u003c\/strong\u003e\u003c\/p\u003e\r\n\u003col type=\"1\"\u003e\r\n\u003cli\u003e\u003cstrong\u003eStop the dosing\u003c\/strong\u003e and remove the probe from its probe holder\u003c\/li\u003e\r\n\u003cli\u003e\u003cstrong\u003eRinse the tip with clean water\u003c\/strong\u003e and gently dry it, without rubbing the bulb\u003c\/li\u003e\r\n\u003cli\u003e\u003cstrong\u003eImmerse it in the standard solution\u003c\/strong\u003e (pH 7) and wait for the reading to stabilize\u003c\/li\u003e\r\n\u003cli\u003e\u003cstrong\u003eConfirm the calibration\u003c\/strong\u003e on the device by following the menu sequence\u003c\/li\u003e\r\n\u003cli\u003e\u003cstrong\u003eRinse, reattach the probe\u003c\/strong\u003e to the probe holder, and resume dosing\u003c\/li\u003e\r\n\u003c\/ol\u003e\r\n\u003cp\u003e\u003cstrong\u003eTwo tips to avoid disappointment:\u003c\/strong\u003e\u003c\/p\u003e\r\n\u003cul\u003e\r\n\u003cli\u003e\u003cstrong\u003eThe calibration solution has expired.\u003c\/strong\u003e This is the number one cause of failed calibrations: if the equipment cannot calibrate, try using fresh solution before suspecting the probe\u003c\/li\u003e\r\n\u003cli\u003e\u003cstrong\u003eDon’t let the probe dry out.\u003c\/strong\u003e An electrode that spends hours exposed to the air with a dry bulb rarely recovers. If you remove it, store it with its cap and storage solution\u003c\/li\u003e\r\n\u003c\/ul\u003e\r\n\u003cp\u003eFor the exact menu sequence for \u003cstrong\u003eyour specific model\u003c\/strong\u003e, consult the manufacturer’s manual or contact us: the steps vary slightly between models in the series.\u003c\/p\u003e\r\n\u003ch2\u003eQuick Diagnosis: From Symptom to Part\u003c\/h2\u003e\r\n\u003ctable style=\"width: 100%; border-collapse: collapse; margin: 15px 0 30px 0; border: 1px solid #d6dde1;\"\u003e\r\n\u003cthead style=\"border: 1px solid #d6dde1; background-color: #f2f6f7; padding: 10px 12px; text-align: left; vertical-align: top;\"\u003e\r\n\u003ctr class=\"header\"\u003e\r\n\u003cth style=\"border: 1px solid #d6dde1; background-color: #f2f6f7; padding: 10px 12px; text-align: left; vertical-align: top;\"\u003eSymptom\u003c\/th\u003e\r\n\u003cth style=\"border: 1px solid #d6dde1; background-color: #f2f6f7; padding: 10px 12px; text-align: left; vertical-align: top;\"\u003eMost Likely Cause\u003c\/th\u003e\r\n\u003cth style=\"border: 1px solid #d6dde1; background-color: #f2f6f7; padding: 10px 12px; text-align: left; vertical-align: top;\"\u003eWhat to Check\u003c\/th\u003e\r\n\u003c\/tr\u003e\r\n\u003c\/thead\u003e\r\n\u003ctbody\u003e\r\n\u003ctr class=\"odd\"\u003e\r\n\u003ctd style=\"border: 1px solid #d6dde1; padding: 10px 12px; vertical-align: top;\"\u003e\u003cstrong\u003eThe pH reading on the display does not match the analyzer\u003c\/strong\u003e\u003c\/td\u003e\r\n\u003ctd style=\"border: 1px solid #d6dde1; padding: 10px 12px; vertical-align: top;\"\u003eProbe is out of calibration or worn out\u003c\/td\u003e\r\n\u003ctd style=\"border: 1px solid #d6dde1; padding: 10px 12px; vertical-align: top;\"\u003eCalibrate with a new solution; if it drifts over time, replace the probe\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr class=\"even\"\u003e\r\n\u003ctd style=\"border: 1px solid #d6dde1; padding: 10px 12px; vertical-align: top;\"\u003eI can’t calibrate the equipment\u003c\/td\u003e\r\n\u003ctd style=\"border: 1px solid #d6dde1; padding: 10px 12px; vertical-align: top;\"\u003eSolution has expired or the probe is worn out\u003c\/td\u003e\r\n\u003ctd style=\"border: 1px solid #d6dde1; padding: 10px 12px; vertical-align: top;\"\u003eUse a new solution first; then check the probe\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr class=\"odd\"\u003e\r\n\u003ctd style=\"border: 1px solid #d6dde1; padding: 10px 12px; vertical-align: top;\"\u003eThe reading takes a long time to stabilize\u003c\/td\u003e\r\n\u003ctd style=\"border: 1px solid #d6dde1; padding: 10px 12px; vertical-align: top;\"\u003eSensor at the end of its service life\u003c\/td\u003e\r\n\u003ctd style=\"border: 1px solid #d6dde1; padding: 10px 12px; vertical-align: top;\"\u003eSensor\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr class=\"even\"\u003e\r\n\u003ctd style=\"border: 1px solid #d6dde1; padding: 10px 12px; vertical-align: top;\"\u003e\u003cstrong\u003eDosing less than programmed\u003c\/strong\u003e\u003c\/td\u003e\r\n\u003ctd style=\"border: 1px solid #d6dde1; padding: 10px 12px; vertical-align: top;\"\u003eHardened peristaltic tube\u003c\/td\u003e\r\n\u003ctd style=\"border: 1px solid #d6dde1; padding: 10px 12px; vertical-align: top;\"\u003eSantoprene tube\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr class=\"odd\"\u003e\r\n\u003ctd style=\"border: 1px solid #d6dde1; padding: 10px 12px; vertical-align: top;\"\u003ePumps but does not draw in product\u003c\/td\u003e\r\n\u003ctd style=\"border: 1px solid #d6dde1; padding: 10px 12px; vertical-align: top;\"\u003eExpired tubing, clogged foot filter, or air\u003c\/td\u003e\r\n\u003ctd style=\"border: 1px solid #d6dde1; padding: 10px 12px; vertical-align: top;\"\u003eTube, foot filter, suction connections\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr class=\"even\"\u003e\r\n\u003ctd style=\"border: 1px solid #d6dde1; padding: 10px 12px; vertical-align: top;\"\u003eProduct leaking from the head\u003c\/td\u003e\r\n\u003ctd style=\"border: 1px solid #d6dde1; padding: 10px 12px; vertical-align: top;\"\u003ePunctured hose\u003c\/td\u003e\r\n\u003ctd style=\"border: 1px solid #d6dde1; padding: 10px 12px; vertical-align: top;\"\u003eHose; check inside the head\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr class=\"odd\"\u003e\r\n\u003ctd style=\"border: 1px solid #d6dde1; padding: 10px 12px; vertical-align: top;\"\u003eThe rollers turn with difficulty or make noise\u003c\/td\u003e\r\n\u003ctd style=\"border: 1px solid #d6dde1; padding: 10px 12px; vertical-align: top;\"\u003eWorn roller holder\u003c\/td\u003e\r\n\u003ctd style=\"border: 1px solid #d6dde1; padding: 10px 12px; vertical-align: top;\"\u003eRoller holder\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr class=\"even\"\u003e\r\n\u003ctd style=\"border: 1px solid #d6dde1; padding: 10px 12px; vertical-align: top;\"\u003eLeak at the probe connection point\u003c\/td\u003e\r\n\u003ctd style=\"border: 1px solid #d6dde1; padding: 10px 12px; vertical-align: top;\"\u003eProbe holder or its seal\u003c\/td\u003e\r\n\u003ctd style=\"border: 1px solid #d6dde1; padding: 10px 12px; vertical-align: top;\"\u003eProbe holder\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr class=\"odd\"\u003e\r\n\u003ctd style=\"border: 1px solid #d6dde1; padding: 10px 12px; vertical-align: top;\"\u003eLevel error when the tank is full\u003c\/td\u003e\r\n\u003ctd style=\"border: 1px solid #d6dde1; padding: 10px 12px; vertical-align: top;\"\u003eLevel probe or suction tube\u003c\/td\u003e\r\n\u003ctd style=\"border: 1px solid #d6dde1; padding: 10px 12px; vertical-align: top;\"\u003eSuction circuit\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003c\/tbody\u003e\r\n\u003c\/table\u003e\r\n\u003cp\u003e \u003c\/p\u003e\r\n\u003ch2\u003eMaintenance of the e-Series pH\u003c\/h2\u003e\r\n\u003cul\u003e\r\n\u003cli\u003e\u003cstrong\u003eFlush the circuit with clean water at the end of the season.\u003c\/strong\u003e Leaving acid to sit for six months causes the tubing to harden and the injection point to crystallize. This is the most effective way to prevent breakdowns\u003c\/li\u003e\r\n\u003cli\u003e\u003cstrong\u003eCheck the foot filter every time you change the bottle\u003c\/strong\u003e\u003c\/li\u003e\r\n\u003cli\u003e\u003cstrong\u003eKeep the probe moist\u003c\/strong\u003e if you disassemble the unit: use the cap and preservative solution\u003c\/li\u003e\r\n\u003cli\u003e\u003cstrong\u003eReplace the calibration solution every season\u003c\/strong\u003e, even if there is liquid left in the bottle\u003c\/li\u003e\r\n\u003cli\u003e\u003cstrong\u003eMonitor the injection point\u003c\/strong\u003e: limescale buildup occurs gradually\u003c\/li\u003e\r\n\u003cli\u003eAlways wear\u003cstrong\u003egloves and goggles\u003c\/strong\u003e when opening the head: there are traces of concentrated product inside\u003c\/li\u003e\r\n\u003c\/ul\u003e\r\n\u003cp\u003eCan’t find a replacement part for your e-Series pH CTX, or do you need help with calibration? Call us at \u003cstrong\u003e91 128 55 90\u003c\/strong\u003e or contact us via the \u003ca href=\"\/en\/pages\/contact\"\u003econtact form\u003c\/a\u003e, specifying the \u003cstrong\u003eexact model of your equipment\u003c\/strong\u003e and, if it’s a reading issue, what the display shows on your analyzer. And keep these two rules in mind to ensure this pump works properly: \u003cstrong\u003ecalibrate it at least at the start of the season\u003c\/strong\u003e and \u003cstrong\u003ereplace the standard solution every year\u003c\/strong\u003e. See also \u003ca href=\"\/en\/collections\/spare-parts-metering-pumps\"\u003ereplacement parts for dosing pumps\u003c\/a\u003e, \u003ca href=\"\/en\/collections\/automatic-ph-control\"\u003eautomatic pH control\u003c\/a\u003e, \u003ca href=\"\/en\/collections\/swimming-pool-water-analysis\"\u003ewater analysis\u003c\/a\u003e, and \u003ca href=\"\/en\/collections\/technical-service\"\u003etechnical service\u003c\/a\u003e.\u003c\/p\u003e","products":[{"product_id":"electrodo-de-ph-de-15-metros","title":"Seko pH electrode, 1.5 m 9900105001","description":"\u003cp\u003eThe pH electrode is the measuring part and the first to wear out. When readings drift, take long to settle or calibration no longer holds, it is time to replace it. This is a general-purpose Seko electrode with epoxy body and BNC connector.\u003c\/p\u003e\u003ch3\u003eSpare part details\u003c\/h3\u003e\u003cul\u003e\u003cli\u003eManufacturer's description: pH probe\/electrode SPH-1S 1.5\u003c\/li\u003e\u003cli\u003eManufacturer code: 9900105001\u003c\/li\u003e\u003cli\u003eManufacturer: Seko\u003c\/li\u003e\u003c\/ul\u003e\u003ch3\u003eTechnical data\u003c\/h3\u003e\u003cul\u003e\u003cli\u003eMeasuring range: pH 2 to 12\u003c\/li\u003e\u003cli\u003eMinimum water conductivity: 50 µS\/cm\u003c\/li\u003e\u003cli\u003eTemperature: 0 to 60 °C\u003c\/li\u003e\u003cli\u003eBody: epoxy, glass membrane\u003c\/li\u003e\u003cli\u003eElectrolyte: gel\u003c\/li\u003e\u003cli\u003eDiameter: 12 mm\u003c\/li\u003e\u003cli\u003e1.5 m cable with BNC connector\u003c\/li\u003e\u003c\/ul\u003e\u003ch3\u003eCompatibility\u003c\/h3\u003e\u003cp\u003eFor measuring or control units that accept a pH electrode with a BNC connector. Check your unit's manual for the type of probe it accepts.\u003c\/p\u003e\u003ch3\u003eHow to check it is the right part\u003c\/h3\u003e\u003cp\u003eCheck in your unit's manual which type of probe or accessory it accepts (connection, cable length, diameter). If in doubt, send us a photo of the unit's rating label and of the current part before ordering and we will confirm it.\u003c\/p\u003e\u003ch3\u003eReplacement\u003c\/h3\u003e\u003cp\u003eBefore working on the unit, disconnect it from the mains and stop the filtration.\u003c\/p\u003e","brand":"Seko","offers":[{"title":"Default Title","offer_id":54378476241243,"sku":"05BD9900105001","price":74.9,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0990\/9600\/2907\/files\/electrodo-ph-seko-1-5m-estudio.png?v=1792838394"},{"product_id":"tubo-peristaltico-santopreno-6x10mm-conex-4x6","title":"Seko Santoprene peristaltic tube 9900090057 (6x10 mm, 4x6 connection)","description":"\u003cp\u003eThe tube is the part of the peristaltic pump that wears most: with use it loses elasticity and the pump stops drawing or doses less. It comes fitted with its connectors at both ends so it can be swapped without further adjustment.\u003c\/p\u003e\u003ch3\u003eSpare part details\u003c\/h3\u003e\u003cul\u003e\u003cli\u003eManufacturer's description: Santoprene peristaltic tube 6x10 mm\u003c\/li\u003e\u003cli\u003eManufacturer code: 9900090057\u003c\/li\u003e\u003cli\u003eManufacturer: Seko\u003c\/li\u003e\u003c\/ul\u003e\u003ch3\u003eTechnical data\u003c\/h3\u003e\u003cul\u003e\u003cli\u003eMaterial: Santoprene\u003c\/li\u003e\u003cli\u003eTube diameter: 6 x 10 mm\u003c\/li\u003e\u003cli\u003eConnection to 4 x 6 mm micro-tube\u003c\/li\u003e\u003cli\u003eFitted with connectors and glands at both ends\u003c\/li\u003e\u003c\/ul\u003e\u003ch3\u003eCompatibility\u003c\/h3\u003e\u003cp\u003eSeko lists it as a spare part for its peristaltic pumps:\u003c\/p\u003e\u003cul\u003e\u003cli\u003eSeko PR4\u003c\/li\u003e\u003cli\u003eSeko PR7\u003c\/li\u003e\u003cli\u003eSeko PE1.5\u003c\/li\u003e\u003cli\u003eSeko PE5.0\u003c\/li\u003e\u003c\/ul\u003e\u003ch3\u003eHow to check it is the right part\u003c\/h3\u003e\u003cp\u003eThe model name is shown on the unit's rating label and in its manual. If your unit is one of the models listed, this is the right part for it. If in doubt, send us a photo of the label before ordering and we will confirm it.\u003c\/p\u003e\u003ch3\u003eReplacement\u003c\/h3\u003e\u003cp\u003eSeko recommends always fitting the new tube in the pump's direction of rotation (clockwise). Before working on the unit, disconnect it from the mains and stop the filtration.\u003c\/p\u003e","brand":"Seko","offers":[{"title":"Default Title","offer_id":54378485842267,"sku":"13RP9900090057","price":18.9,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0990\/9600\/2907\/files\/tubo-santoprene-seko-9900090057-estudio.png?v=1792856646"},{"product_id":"portasondas-pss-3-largo","title":"Seko PSS3 long probe holder 9900106670","description":"\u003cp\u003eThe probe holder secures the pH or redox electrode inside the pipe and keeps it in contact with the water. If it is broken, leaks or the probe is not held firmly, readings are no longer reliable.\u003c\/p\u003e\u003ch3\u003eSpare part details\u003c\/h3\u003e\u003cul\u003e\u003cli\u003eManufacturer's description: Pressurised probe holder PSS 3\u003c\/li\u003e\u003cli\u003eManufacturer code: 9900106670\u003c\/li\u003e\u003cli\u003eManufacturer: Seko\u003c\/li\u003e\u003c\/ul\u003e\u003ch3\u003eTechnical data\u003c\/h3\u003e\u003cul\u003e\u003cli\u003eProcess connection: ½\" BSP male\u003c\/li\u003e\u003cli\u003eProbe connection: PG 13.5 or Ø 12 mm\u003c\/li\u003e\u003cli\u003eMaximum temperature: 60 °C\u003c\/li\u003e\u003cli\u003eMaximum pressure: 7 bar\u003c\/li\u003e\u003cli\u003eMaterial: PVC\u003c\/li\u003e\u003c\/ul\u003e\u003ch3\u003eCompatibility\u003c\/h3\u003e\u003cp\u003eAccepts probes with PG 13.5 thread or Ø 12 mm body. Check your probe's connection before ordering.\u003c\/p\u003e\u003ch3\u003eHow to check it is the right part\u003c\/h3\u003e\u003cp\u003eCheck in your unit's manual which type of probe or accessory it accepts (connection, cable length, diameter). If in doubt, send us a photo of the unit's rating label and of the current part before ordering and we will confirm it.\u003c\/p\u003e\u003ch3\u003eReplacement\u003c\/h3\u003e\u003cp\u003eSeko specifies installing the probe vertically or tilted at most 45° in the direction of flow, with the holder between two shut-off valves so it can be isolated for maintenance. Before working on the unit, disconnect it from the mains and stop the filtration.\u003c\/p\u003e","brand":"Seko","offers":[{"title":"Default Title","offer_id":54378485940571,"sku":"13RP9900106670","price":23.95,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0990\/9600\/2907\/files\/portasondas-seko-pss3-largo-estudio.png?v=1792838672"},{"product_id":"porta-rodillos-bomba-persitaltica-seko","title":"Seko roller holder RIC0151035","description":"\u003cp\u003eThe roller holder is the rotating part that presses the peristaltic pump tube to push the product along. If the rollers are worn or the part is broken, the pump turns but does not dose.\u003c\/p\u003e\u003ch3\u003eSpare part details\u003c\/h3\u003e\u003cul\u003e\u003cli\u003eManufacturer's description: Peristaltic roller holder\u003c\/li\u003e\u003cli\u003eManufacturer code: RIC0151035\u003c\/li\u003e\u003cli\u003eManufacturer: Seko\u003c\/li\u003e\u003c\/ul\u003e\u003ch3\u003eTechnical data\u003c\/h3\u003e\u003cul\u003e\u003cli\u003eHigh mechanical strength material\u003c\/li\u003e\u003c\/ul\u003e\u003ch3\u003eCompatibility\u003c\/h3\u003e\u003cp\u003eSeko lists it as a spare part for its peristaltic pumps:\u003c\/p\u003e\u003cul\u003e\u003cli\u003eSeko PR1\u003c\/li\u003e\u003cli\u003eSeko PR4\u003c\/li\u003e\u003cli\u003eSeko PR7\u003c\/li\u003e\u003cli\u003eSeko PE1.5\u003c\/li\u003e\u003cli\u003eSeko PE3.0\u003c\/li\u003e\u003cli\u003eSeko PE5.0\u003c\/li\u003e\u003c\/ul\u003e\u003ch3\u003eHow to check it is the right part\u003c\/h3\u003e\u003cp\u003eThe model name is shown on the unit's rating label and in its manual. If your unit is one of the models listed, this is the right part for it. If in doubt, send us a photo of the label before ordering and we will confirm it.\u003c\/p\u003e\u003ch3\u003eReplacement\u003c\/h3\u003e\u003cp\u003eBefore working on the unit, disconnect it from the mains and stop the filtration.\u003c\/p\u003e","brand":"Seko","offers":[{"title":"Default Title","offer_id":54378486071643,"sku":"13RP9900151024","price":15.95,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0990\/9600\/2907\/files\/21484.jpg?v=1792146734"},{"product_id":"solucion-tampon-ph-7-50-ml","title":"Seko pH 7 buffer solution (50 ml) 9900102002","description":"\u003cp\u003eBuffer solutions have a known pH value and are used to calibrate the pH electrode. Without regular calibration the reading drifts and the controller doses too much or too little. This is the pH 7 solution.\u003c\/p\u003e\u003ch3\u003eSpare part details\u003c\/h3\u003e\u003cul\u003e\u003cli\u003eManufacturer code: 9900102002\u003c\/li\u003e\u003cli\u003eManufacturer: Seko\u003c\/li\u003e\u003c\/ul\u003e\u003cp\u003eThe manufacturer does not publish a data sheet for this reference on its official website, so we only give the product's own details.\u003c\/p\u003e\u003ch3\u003eCompatibility\u003c\/h3\u003e\u003cp\u003eFor calibrating pH electrodes. Follow the calibration procedure in your unit's manual.\u003c\/p\u003e\u003ch3\u003eHow to check it is the right part\u003c\/h3\u003e\u003cp\u003eCheck in your unit's manual which type of probe or accessory it accepts (connection, cable length, diameter). If in doubt, send us a photo of the unit's rating label and of the current part before ordering and we will confirm it.\u003c\/p\u003e\u003ch3\u003eReplacement\u003c\/h3\u003e\u003cp\u003eNo dismantling needed. For calibration, follow the steps in your controller's manual.\u003c\/p\u003e","brand":"Seko","offers":[{"title":"Default Title","offer_id":54378529915227,"sku":"13RP9900102002","price":5.99,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0990\/9600\/2907\/files\/19584.jpg?v=1792147508"},{"product_id":"collarin-para-tuberia-de-pvc-50-1-2","title":"Collar for PVC pipe 50-1\/2\"","description":"\u003cul\u003e\r\n\u003cli\u003eTapping collar\u003c\/li\u003e\r\n\u003cli\u003ePP material\u003c\/li\u003e\r\n\u003cli\u003e1\/2\" threaded outlet\u003c\/li\u003e\r\n\u003cli\u003eFor installation on 50 mm (1 1\/2\") pipe\u003c\/li\u003e\r\n\u003cli\u003eAccording to standard - PVC-U: EN 1452-2 \/ PP: ISO 3609 \/ DIN 8077 \/ UNI 8318\u003c\/li\u003e\r\n\u003c\/ul\u003e","brand":"Quimipool","offers":[{"title":"Default Title","offer_id":54378540269915,"sku":"09PV0506019","price":2.59,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0990\/9600\/2907\/files\/11915.jpg?v=1792147624"},{"product_id":"electrodo-de-ph-de-2-metros-hanna-hi2114p","title":"Hanna HI2114P pH electrode, 2 m","description":"\u003cp\u003eThe pH electrode is the measuring part and the first to wear out. When readings drift, take long to settle or calibration no longer holds, it is time to replace it. This Hanna model has a 2 m cable and BNC connector.\u003c\/p\u003e\u003ch3\u003eSpare part details\u003c\/h3\u003e\u003cul\u003e\u003cli\u003eManufacturer's description: pH electrode, plastic body, gel electrolyte, microporous fibre junction, BNC connector, 2 m\u003c\/li\u003e\u003cli\u003eManufacturer code: HI2114P\u003c\/li\u003e\u003cli\u003eManufacturer: Hanna Instruments\u003c\/li\u003e\u003c\/ul\u003e\u003ch3\u003eTechnical data\u003c\/h3\u003e\u003cul\u003e\u003cli\u003eMeasuring range: pH 0 to 13\u003c\/li\u003e\u003cli\u003eBody: PEI\u003c\/li\u003e\u003cli\u003eElectrolyte: gel\u003c\/li\u003e\u003cli\u003eTip: spherical (Ø 7.5 mm)\u003c\/li\u003e\u003cli\u003eMaximum pressure: 3 bar\u003c\/li\u003e\u003cli\u003eOperating temperature: 0 to 80 °C\u003c\/li\u003e\u003cli\u003eOuter diameter: 12 mm\u003c\/li\u003e\u003cli\u003eOverall length: 122 mm\u003c\/li\u003e\u003cli\u003e2 m coaxial cable with BNC connector\u003c\/li\u003e\u003cli\u003eThread: ¾\" x 16 UNF\u003c\/li\u003e\u003c\/ul\u003e\u003ch3\u003eCompatibility\u003c\/h3\u003e\u003cp\u003eFor measuring or control units that accept a pH electrode with a BNC connector. Check your unit's manual for the type of probe it accepts.\u003c\/p\u003e\u003ch3\u003eHow to check it is the right part\u003c\/h3\u003e\u003cp\u003eCheck in your unit's manual which type of probe or accessory it accepts (connection, cable length, diameter). If in doubt, send us a photo of the unit's rating label and of the current part before ordering and we will confirm it.\u003c\/p\u003e\u003ch3\u003eReplacement\u003c\/h3\u003e\u003cp\u003eBefore working on the unit, disconnect it from the mains and stop the filtration.\u003c\/p\u003e","brand":"Hanna","offers":[{"title":"Default Title","offer_id":54378792419675,"sku":"05BDHI2114P","price":76.9,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0990\/9600\/2907\/files\/20932.jpg?v=1792150183"},{"product_id":"kit-electrodo-de-ph-astralpool","title":"PH electrode kit Astralpool","description":"\u003cul\u003e\r\n\u003cli\u003ePH electrode kit.\u003c\/li\u003e\r\n\u003cli\u003eManufacturer: Astralpool.\u003c\/li\u003e\r\n\u003cli\u003eCode: 70335.\u003c\/li\u003e\r\n\u003cli\u003e\u003cstrong\u003eThe kit includes:\u003c\/strong\u003e\u003cbr \/\u003e- pH electrode\u003cbr \/\u003e- \u003cspan\u003ebuffer solutions: pH7 and pH9\u003c\/span\u003e\u003cbr \/\u003e- electrode holder\u003cbr \/\u003e- 2 collars\u003c\/li\u003e\r\n\u003cli\u003eRecommendations for use and maintenance\u003cspan style=\"color: #2c9ffd;\"\u003e\u003cstrong\u003e\u003ca href=\"\/en\"\u003e\u003cspan style=\"color: #2c9ffd;\"\u003e(see documents\u003c\/span\u003e\u003c\/a\u003e\u003c\/strong\u003e\u003c\/span\u003e)\u003c\/li\u003e\r\n\u003c\/ul\u003e","brand":"Astralpool","offers":[{"title":"Default Title","offer_id":54379157029211,"sku":"05BD70335","price":79.9,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0990\/9600\/2907\/files\/17695.jpg?v=1792151233"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0990\/9600\/2907\/collections\/1149.jpg?v=1792140572","url":"https:\/\/www.quimipool.com\/en\/collections\/spare-parts-ctx-e-series-ph.oembed","provider":"Quimipool","version":"1.0","type":"link"}