{"title":"Reagents and accessories for photometers","description":"\u003cp\u003eReagents for use with photometers or manual test kits. Here you will find liquid, powder or tablet reagents from Lovibond, Hanna, \u003ca href=\"\/en\/collections\/swimming-pool-filters-astralpool\" class=\"pmsil\" title=\"AstralPool\"\u003eAstralpool\u003c\/a\u003e and PrimeLAB, as well as accessories such as cuvettes and test strips.\u003c\/p\u003e","products":[{"product_id":"reactivo-dpd-n1-cloro-libre-residual-fotometro","title":"Lovibond DPD No. 1 free chlorine tablets 511051BT – 250 pcs for photometer","description":"\u003cp\u003eFree chlorine is the chlorine that disinfects. It is the value to check daily, and it decides whether the water is protected or not. The DPD No. 1 tablet is the reference reagent for measuring it with a Lovibond photometer: one tablet, one reading, no guessing colours by eye.\u003c\/p\u003e\n\u003ch2\u003eWhat it measures\u003c\/h2\u003e\n\u003cp\u003eDPD No. 1 measures \u003cstrong\u003efree chlorine\u003c\/strong\u003e: the active part of chlorine (hypochlorous acid and hypochlorite ion). If you also add a \u003ca href=\"https:\/\/www.quimipool.com\/en\/products\/dpd-reagent-no-3-total-chlorine-photometer\"\u003eDPD No. 3 Evo\u003c\/a\u003e tablet to the same sample, you get total chlorine; the difference between the two is combined chlorine (chloramines), which causes the chlorine smell and eye irritation.\u003c\/p\u003e\n\u003cp\u003eKeep free chlorine between \u003cstrong\u003e1 and 1.5 ppm\u003c\/strong\u003e. Remember that chlorine efficiency depends on pH: at pH 7.8 you need twice as much chlorine as at pH 7.2 for the same disinfection. Always measure both values.\u003c\/p\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eReagent: Lovibond DPD No. 1 photometer tablets.\u003c\/li\u003e\n\u003cli\u003eContents: 250 individually sealed tablets. One tablet per test.\u003c\/li\u003e\n\u003cli\u003eRange: 0.01–6.0 mg\/L free chlorine (method M100 on MD 200).\u003c\/li\u003e\n\u003cli\u003eBoric acid-free formulation (Lovibond Green Chemistry).\u003c\/li\u003e\n\u003cli\u003eManufacturer reference: 511051BT.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eCompatible instruments\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eLovibond MD 100, MD 110, MD 150 and MD 200 photometers.\u003c\/li\u003e\n\u003cli\u003eLovibond Scuba II.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThis is not the tablet for Pooltester kits: those comparators use DPD No. 1 Rapid, formulated for visual reading.\u003c\/p\u003e\n\u003ch2\u003eHow to use\u003c\/h2\u003e\n\u003col\u003e\n\u003cli\u003eZero the photometer with the cuvette filled with pool water.\u003c\/li\u003e\n\u003cli\u003eEmpty the cuvette leaving a few drops, add one DPD No. 1 tablet and crush it.\u003c\/li\u003e\n\u003cli\u003eTop up with the sample, mix until dissolved and read immediately.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Lovibond","offers":[{"title":"Default Title","offer_id":54378295034203,"sku":"01IES03009","price":15.35,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0990\/9600\/2907\/files\/lovibond-21191-estudio_017e3886-a851-45cd-8e41-cfaafe615ac9.png?v=1793374643"},{"product_id":"reactivo-dpd-n3-cloro-total-fotometro","title":"Lovibond DPD No. 3 Evo total chlorine tablets 511421BT – 250 pcs for photometer","description":"\u003cp\u003eIf the water smells strongly of chlorine or stings the eyes, there is usually not too much chlorine: there are too many chloramines. To know for sure, measure total chlorine and compare it with free chlorine. DPD No. 3 Evo, together with \u003ca href=\"https:\/\/www.quimipool.com\/en\/products\/dpd-reagent-no-1-free-chlorine-residual-photometer\"\u003eDPD No. 1\u003c\/a\u003e, gives you that figure with your Lovibond photometer.\u003c\/p\u003e\n\u003ch2\u003eWhat it measures\u003c\/h2\u003e\n\u003cp\u003eDPD No. 3 is added to the sample in which you have already measured free chlorine with DPD No. 1. The result is \u003cstrong\u003etotal chlorine\u003c\/strong\u003e. Subtracting free chlorine gives \u003cstrong\u003ecombined chlorine\u003c\/strong\u003e (chloramines): they form when chlorine reacts with sweat and other bather residues, irritate eyes and mucous membranes, cause the typical chlorine smell and barely disinfect.\u003c\/p\u003e\n\u003ch2\u003eWhat is new in the Evo version\u003c\/h2\u003e\n\u003cp\u003eIt is Lovibond's new formulation with low potassium iodide and no boric acid. It gives the same results as the classic DPD No. 3 and is safer to handle. It replaces the previous reference 511081BT.\u003c\/p\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eReagent: Lovibond DPD No. 3 Evo photometer tablets.\u003c\/li\u003e\n\u003cli\u003eContents: 250 individually sealed tablets.\u003c\/li\u003e\n\u003cli\u003eRange: 0.01–6.0 mg\/L total chlorine (method M100 on MD 200; 0.1–6.0 mg\/L on Scuba II).\u003c\/li\u003e\n\u003cli\u003eAlways used together with DPD No. 1: each total chlorine test uses one of each.\u003c\/li\u003e\n\u003cli\u003eManufacturer reference: 511421BT.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eCompatible instruments\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eLovibond MD 110, MD 150 and MD 200 photometers.\u003c\/li\u003e\n\u003cli\u003eLovibond Scuba II.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eHow to use\u003c\/h2\u003e\n\u003col\u003e\n\u003cli\u003eMeasure free chlorine with DPD No. 1 and note the value.\u003c\/li\u003e\n\u003cli\u003eAdd one DPD No. 3 Evo tablet to the same cuvette and crush it until dissolved.\u003c\/li\u003e\n\u003cli\u003eWait 2 minutes and read: that is total chlorine. Combined chlorine = total − free.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Lovibond","offers":[{"title":"Default Title","offer_id":54378295296347,"sku":"01IES03014","price":16.9,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0990\/9600\/2907\/files\/lovibond-23850-estudio_718a5edd-e483-46f0-bf80-63d79cf8fc28.png?v=1793374644"},{"product_id":"reactivo-para-analisis-acido-cianurico","title":"Lovibond CyA-Test Cyanuric Acid Tablets 511371BT – 250 pcs","description":"\u003cp\u003eIf your pool is outdoors and you use chlorine tablets or dichlor granules, cyanuric acid (stabiliser) builds up in the water with every dose. At the right level it protects chlorine from the sun. In excess it does the opposite: \u003cstrong\u003ethe chlorine test reads fine, but the water is not disinfected\u003c\/strong\u003e. This is a common cause of cloudy or green water with \"correct chlorine\". These Lovibond tablets let you measure it with your photometer or MINIKIT and know when to act.\u003c\/p\u003e\n\n\u003ch2\u003eWhat it measures and why it matters\u003c\/h2\u003e\n\u003cp\u003eCyanuric acid protects free chlorine from ultraviolet radiation and reduces its consumption by up to 50% in outdoor pools. The problem is that it does not break down or evaporate: every trichlor tablet or dichlor dose raises it a little more.\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003e\u003cstrong\u003eRecommended range: 25–30 ppm.\u003c\/strong\u003e Above this, protection barely improves.\u003c\/li\u003e\n  \u003cli\u003e\u003cstrong\u003eLegal limit in Spain (RD 742\/2013): 75 ppm.\u003c\/strong\u003e Beyond this, the stabiliser progressively blocks the chlorine.\u003c\/li\u003e\n  \u003cli\u003e\u003cstrong\u003eAbove 150 mg\/L\u003c\/strong\u003e Spanish regulations require public pools to close.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eNo chemical product removes it. If the level is high, the only fix is to replace part of the water.\u003c\/p\u003e\n\n\u003ch2\u003eFeatures\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eReagent: Lovibond CyA-Test, tablets.\u003c\/li\u003e\n  \u003cli\u003eContents: 250 individually packed tablets. One tablet per test: 250 tests.\u003c\/li\u003e\n  \u003cli\u003eMethod: turbidimetry with melamine (Lovibond method M160).\u003c\/li\u003e\n  \u003cli\u003eMeasuring range: 10–160 mg\/L CyA on MD photometers; 20–200 mg\/L CyA with the MINIKIT AF 422.\u003c\/li\u003e\n  \u003cli\u003eManufacturer reference: 511371BT · EAN 4049991091471.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eCompatible devices\u003c\/h2\u003e\n\u003cp\u003eThis is the Lovibond CyA-Test refill tablet, suitable for:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eLovibond MD 100 photometer (cyanuric acid versions)\u003c\/li\u003e\n  \u003cli\u003eLovibond MD 110 3in1 and 4in1 photometer\u003c\/li\u003e\n  \u003cli\u003eLovibond MD 200 photometer\u003c\/li\u003e\n  \u003cli\u003eLovibond Scuba II photometer\u003c\/li\u003e\n  \u003cli\u003eLovibond MINIKIT AF 422 (cyanuric acid)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eIf you are unsure about your model, check the name on the device or contact our technical service.\u003c\/p\u003e\n\n\u003ch2\u003eWhen to test\u003c\/h2\u003e\n\u003cp\u003eWhen filling the pool and regularly throughout the season, especially if you use trichlor or dichlor. If you have a salt chlorinator or use sodium hypochlorite, the treatment does not raise cyanuric acid, but it is worth checking at the start of the season.\u003c\/p\u003e","brand":"Lovibond","offers":[{"title":"Default Title","offer_id":54378295558491,"sku":"01IES08345","price":22.71,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0990\/9600\/2907\/files\/lovibond-21195-estudio_0abfc36d-910b-4a10-a7a0-75dcd302fad0.png?v=1793374649"},{"product_id":"reactivo-phenol-para-fotometros","title":"Lovibond Phenol Red Photometer pH tablets 511771BT – 250 pcs","description":"\u003cp\u003eWith a high pH, chlorine works at half strength: at pH 7.8 you need twice as much chlorine as at pH 7.2 for the same disinfection. That is why pH is measured together with chlorine. The Phenol Red Photometer tablet is the pH reagent for Lovibond photometers.\u003c\/p\u003e\n\u003ch2\u003eWhat it measures and what to aim for\u003c\/h2\u003e\n\u003cp\u003eIt measures water \u003cstrong\u003epH\u003c\/strong\u003e between 6.5 and 8.4. Keep pH between \u003cstrong\u003e7.2 and 7.4\u003c\/strong\u003e: chlorine then works at its best and less product is consumed. A pH out of range also promotes corrosion or scaling.\u003c\/p\u003e\n\u003cp\u003eThe tablet contains thiosulphate, which compensates for chlorine interference in pool water readings.\u003c\/p\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eReagent: Lovibond Phenol Red Photometer tablets.\u003c\/li\u003e\n\u003cli\u003eContents: 250 individually sealed tablets. One tablet per test.\u003c\/li\u003e\n\u003cli\u003eRange: pH 6.5–8.4 (method M330).\u003c\/li\u003e\n\u003cli\u003eManufacturer reference: 511771BT.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eCompatible instruments\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eLovibond MD 100, MD 110 and MD 200 photometers.\u003c\/li\u003e\n\u003cli\u003eLovibond Scuba II.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThis is the photometer version. Do not confuse it with comparator Phenol Red or with the Phenol Red Rapid in Pooltester kits: they have a different formulation and give wrong readings in the photometer.\u003c\/p\u003e\n\u003ch2\u003eHow to use\u003c\/h2\u003e\n\u003col\u003e\n\u003cli\u003eZero the photometer with the cuvette filled with pool water.\u003c\/li\u003e\n\u003cli\u003eAdd one Phenol Red Photometer tablet and crush it with the stirring rod.\u003c\/li\u003e\n\u003cli\u003eMix until fully dissolved and read the pH.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Lovibond","offers":[{"title":"Default Title","offer_id":54378312663387,"sku":"01IES03019","price":16.9,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0990\/9600\/2907\/files\/lovibond-21193-estudio_1d169697-2759-4039-8409-42677e9c185a.png?v=1793374649"},{"product_id":"reactivo-liquido-hanna-cloro-libre-300-test","title":"Liquid reagent Hanna for Free Chlorine 300 test","description":"\u003cp\u003eIf you test your pool's chlorine with a Hanna photometer or Checker mini-photometer, this is the reagent you need for a reliable reading. HI93701-F is Hanna's original liquid reagent for \u003cstrong\u003efree chlorine using the DPD method\u003c\/strong\u003e, the same one your meter is programmed for. With a generic or expired reagent, the meter can show values that don't match the actual water and lead you to add too much or too little chlorine.\u003c\/p\u003e\n\n\u003ch2\u003eWhat's included\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eDropper bottles of reagent A (yellow cap) and reagent B (blue cap).\u003c\/li\u003e\n\u003cli\u003eEnough for \u003cstrong\u003e300 tests\u003c\/strong\u003e of free chlorine.\u003c\/li\u003e\n\u003cli\u003eLiquid format: no sachets to open and no powder to dissolve. Just count the drops.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eCompatible meters\u003c\/h2\u003e\n\u003cp\u003eAccording to Hanna, it is suitable for the photometers that measure free chlorine with liquid reagent: HI97701, HI97710, HI97711, HI971044, HI97734, HI97745, HS94104C and HI97101, as well as the free chlorine Checker mini-photometers. The measuring range depends on the meter: 0.00 to 2.50 mg\/L on the Checker and up to 5.00 mg\/L on the photometers.\u003c\/p\u003e\n\n\u003ch2\u003eHow to use it\u003c\/h2\u003e\n\u003col\u003e\n\u003cli\u003eFill a cuvette with 10 mL of pool water, place it in the meter and zero it.\u003c\/li\u003e\n\u003cli\u003eIn another empty cuvette, add 3 drops of reagent A and 3 drops of reagent B and mix them.\u003c\/li\u003e\n\u003cli\u003eAdd 10 mL of sample, close the cuvette and shake gently for about 20 seconds.\u003c\/li\u003e\n\u003cli\u003eClean and dry the cuvette, place it in the meter and read the result in mg\/L (ppm).\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003eAdd the drops to the cuvette first, then the water. Never measure inside the reagent bottle. Always clean the cuvette before placing it in the meter: a fingerprint or a drop on the outside will distort the reading.\u003c\/p\u003e\n\n\u003ch2\u003eStorage\u003c\/h2\u003e\n\u003cp\u003eStore the reagents in a dry place, tightly closed and away from sunlight. Each batch is marked with a lot number and expiry date. An expired or poorly stored reagent is one of the most common causes of incorrect readings.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical specifications\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\u003ctd\u003e\u003cstrong\u003eReference\u003c\/strong\u003e\u003c\/td\u003e\u003ctd\u003eHI93701-F\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\u003ctd\u003eHanna Instruments\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\u003ctd\u003eFree chlorine\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd\u003e\u003cstrong\u003eFormat\u003c\/strong\u003e\u003c\/td\u003e\u003ctd\u003eLiquid, dropper bottles (reagents A and B)\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd\u003e\u003cstrong\u003eNumber of tests\u003c\/strong\u003e\u003c\/td\u003e\u003ctd\u003e300\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\u003ctd\u003e0.00 to 2.50 mg\/L (Checker) \/ up to 5.00 mg\/L (photometers)\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd\u003e\u003cstrong\u003eMethod\u003c\/strong\u003e\u003c\/td\u003e\u003ctd\u003eDPD, adaptation of USEPA method 330.5 and Standard Method 4500-Cl G\u003c\/td\u003e\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eNeed a smaller quantity? We also stock the 100-test version (HS93701-F1) and the free chlorine powder reagent.\u003c\/p\u003e","brand":"Hanna","offers":[{"title":"Default Title","offer_id":54378483351899,"sku":"01ESHI93701-F","price":38.95,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0990\/9600\/2907\/files\/10802416943451-0-estudio.png?v=1793354570"},{"product_id":"reactivo-polvo-hanna-para-cloro-total-100-test","title":"Reagent powder Hanna for Total Chlorine 100 tests","description":"\u003cp\u003eTotal chlorine, compared with free chlorine, tells you how much combined chlorine (chloramines) is in the water: the kind that causes the chlorine smell and eye irritation. Without that measurement you will not know when a shock treatment is needed. The HI93711-01 is Hanna's original reagent for measuring total chlorine.\u003c\/p\u003e\n\u003ch2\u003eWhat's included\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003ePowder reagent, in sachets.\u003c\/li\u003e\n\u003cli\u003eQuantity for \u003cstrong\u003e100 tests\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003eMarked with batch number and expiry date.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eCompatible meters\u003c\/h2\u003e\n\u003cp\u003eSuitable for Hanna benchtop and portable photometers that measure total chlorine. Models listed by Hanna: HI97710, HI97711, HI97734, HI97745, HS94104C, HI97101 and HS94101C. Also used in the Checker HI711.\u003c\/p\u003e\n\u003ch2\u003eTips for a reliable reading\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eFollow the procedure in your meter's manual: the order of the reagents and the reaction time vary by parameter.\u003c\/li\u003e\n\u003cli\u003eAlways add the whole sachet: an incomplete dose gives a false reading.\u003c\/li\u003e\n\u003cli\u003eClean and dry the outside of the cuvette before inserting it: a fingerprint or a drop alters the reading.\u003c\/li\u003e\n\u003cli\u003eDo not use the reagent after its expiry date.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eStorage\u003c\/h2\u003e\n\u003cp\u003eStore the reagent in a dry place, tightly closed and away from sunlight. An expired or poorly stored reagent is one of the most common causes of incorrect readings.\u003c\/p\u003e\n\u003ch2\u003eTechnical specifications\u003c\/h2\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\u003ctd\u003e\u003cstrong\u003eReference\u003c\/strong\u003e\u003c\/td\u003e\u003ctd\u003eHI93711-01\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\u003ctd\u003eHanna Instruments\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\u003ctd\u003eTotal chlorine\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd\u003e\u003cstrong\u003eFormat\u003c\/strong\u003e\u003c\/td\u003e\u003ctd\u003ePowder (sachets)\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd\u003e\u003cstrong\u003eNumber of tests\u003c\/strong\u003e\u003c\/td\u003e\u003ctd\u003e100\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\u003ctd\u003e0.00–5.00 mg\/L\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd\u003e\u003cstrong\u003eMethod\u003c\/strong\u003e\u003c\/td\u003e\u003ctd\u003eDPD, adaptation of USEPA method 330.5 and Standard Method 4500-Cl G\u003c\/td\u003e\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cp\u003eAlso available: HI93711-03 (300 tests).\u003c\/p\u003e","brand":"Hanna","offers":[{"title":"Default Title","offer_id":54378483482971,"sku":"01ESHI93711-01","price":33.9,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0990\/9600\/2907\/files\/21245.jpg?v=1792146630"},{"product_id":"reactivo-liquido-hanna-para-ph-100-test","title":"Liquid reagent Hanna for pH 100 test","description":"\u003cp\u003epH determines how effective the chlorine is and whether swimming is comfortable. With an unbalanced pH, chlorine loses effectiveness and the water irritates eyes and skin. At Quimipool we recommend keeping it between 7.2 and 7.4. The HI93710-01 is Hanna's original reagent for measuring pH.\u003c\/p\u003e\n\u003ch2\u003eWhat's included\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eLiquid reagent, in dropper bottles.\u003c\/li\u003e\n\u003cli\u003eQuantity for \u003cstrong\u003e100 tests\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003eMarked with batch number and expiry date.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eCompatible meters\u003c\/h2\u003e\n\u003cp\u003eSuitable for Hanna benchtop and portable photometers that measure pH.\u003c\/p\u003e\n\u003ch2\u003eTips for a reliable reading\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eFollow the procedure in your meter's manual: the order of the reagents and the reaction time vary by parameter.\u003c\/li\u003e\n\u003cli\u003eClean and dry the outside of the cuvette before inserting it: a fingerprint or a drop alters the reading.\u003c\/li\u003e\n\u003cli\u003eDo not use the reagent after its expiry date.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eStorage\u003c\/h2\u003e\n\u003cp\u003eStore the reagent in a dry place, tightly closed and away from sunlight. An expired or poorly stored reagent is one of the most common causes of incorrect readings.\u003c\/p\u003e\n\u003ch2\u003eTechnical specifications\u003c\/h2\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\u003ctd\u003e\u003cstrong\u003eReference\u003c\/strong\u003e\u003c\/td\u003e\u003ctd\u003eHI93710-01\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\u003ctd\u003eHanna Instruments\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\u003ctd\u003epH\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd\u003e\u003cstrong\u003eFormat\u003c\/strong\u003e\u003c\/td\u003e\u003ctd\u003eLiquid (dropper bottles)\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd\u003e\u003cstrong\u003eNumber of tests\u003c\/strong\u003e\u003c\/td\u003e\u003ctd\u003e100\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\u003ctd\u003e6.5–8.5 pH\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd\u003e\u003cstrong\u003eMethod\u003c\/strong\u003e\u003c\/td\u003e\u003ctd\u003ePhenol red\u003c\/td\u003e\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cp\u003eAlso available: HI93710-03 (300 tests).\u003c\/p\u003e","brand":"Hanna","offers":[{"title":"Default Title","offer_id":54378483777883,"sku":"01ESHI93710-01","price":30.95,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0990\/9600\/2907\/files\/21231.jpg?v=1792146636"},{"product_id":"reactivo-polvo-hanna-acido-cianurico-100-test","title":"Reagent powder Hanna Cyanuric acid 100 test","description":"\u003cp\u003eCyanuric acid (stabiliser) protects chlorine from the sun, but in excess it slows its action: the chlorine reading looks fine and the water is not disinfected. Measuring it tells you when part of the water needs to be renewed. The HI93722-01 is Hanna's original reagent for measuring cyanuric acid.\u003c\/p\u003e\n\u003ch2\u003eWhat's included\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003ePowder reagent, in sachets.\u003c\/li\u003e\n\u003cli\u003eQuantity for \u003cstrong\u003e100 tests\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003eMarked with batch number and expiry date.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eCompatible meters\u003c\/h2\u003e\n\u003cp\u003eSuitable for Hanna benchtop and portable photometers that measure cyanuric acid.\u003c\/p\u003e\n\u003ch2\u003eTips for a reliable reading\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eFollow the procedure in your meter's manual: the order of the reagents and the reaction time vary by parameter.\u003c\/li\u003e\n\u003cli\u003eAlways add the whole sachet: an incomplete dose gives a false reading.\u003c\/li\u003e\n\u003cli\u003eClean and dry the outside of the cuvette before inserting it: a fingerprint or a drop alters the reading.\u003c\/li\u003e\n\u003cli\u003eDo not use the reagent after its expiry date.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eStorage\u003c\/h2\u003e\n\u003cp\u003eStore the reagent in a dry place, tightly closed and away from sunlight. An expired or poorly stored reagent is one of the most common causes of incorrect readings.\u003c\/p\u003e\n\u003ch2\u003eTechnical specifications\u003c\/h2\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\u003ctd\u003e\u003cstrong\u003eReference\u003c\/strong\u003e\u003c\/td\u003e\u003ctd\u003eHI93722-01\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\u003ctd\u003eHanna Instruments\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\u003ctd\u003eCyanuric acid\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd\u003e\u003cstrong\u003eFormat\u003c\/strong\u003e\u003c\/td\u003e\u003ctd\u003ePowder (sachets)\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd\u003e\u003cstrong\u003eNumber of tests\u003c\/strong\u003e\u003c\/td\u003e\u003ctd\u003e100\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\u003ctd\u003e0–80 mg\/L\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd\u003e\u003cstrong\u003eMethod\u003c\/strong\u003e\u003c\/td\u003e\u003ctd\u003eTurbidimetric\u003c\/td\u003e\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cp\u003eAlso available: HI93722-03 (300 tests).\u003c\/p\u003e","brand":"Hanna","offers":[{"title":"Default Title","offer_id":54378483810651,"sku":"01ESHI93722-01","price":63.75,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0990\/9600\/2907\/files\/21263.jpg?v=1792146638"},{"product_id":"reactivo-liquido-para-alcalinidad-total","title":"Liquid reagent Hanna for Total Alkalinity 100 test","description":"\u003cp\u003eAlkalinity acts as a pH buffer. If it is low, pH rises and falls uncontrollably; if it is high, pH is hard to correct. Adjusting alkalinity first saves product and time with pH. The HI93755-01 is Hanna's original reagent for measuring alkalinity.\u003c\/p\u003e\n\u003ch2\u003eWhat's included\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eLiquid reagent, in dropper bottles.\u003c\/li\u003e\n\u003cli\u003eQuantity for \u003cstrong\u003e100 tests\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003eMarked with batch number and expiry date.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eCompatible meters\u003c\/h2\u003e\n\u003cp\u003eSuitable for Hanna benchtop and portable photometers that measure alkalinity. If the water contains chlorine, Hanna recommends using the HI93755-53 chlorine removal reagent first.\u003c\/p\u003e\n\u003ch2\u003eTips for a reliable reading\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eFollow the procedure in your meter's manual: the order of the reagents and the reaction time vary by parameter.\u003c\/li\u003e\n\u003cli\u003eClean and dry the outside of the cuvette before inserting it: a fingerprint or a drop alters the reading.\u003c\/li\u003e\n\u003cli\u003eDo not use the reagent after its expiry date.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eStorage\u003c\/h2\u003e\n\u003cp\u003eStore the reagent in a dry place, tightly closed and away from sunlight. An expired or poorly stored reagent is one of the most common causes of incorrect readings.\u003c\/p\u003e\n\u003ch2\u003eTechnical specifications\u003c\/h2\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\u003ctd\u003e\u003cstrong\u003eReference\u003c\/strong\u003e\u003c\/td\u003e\u003ctd\u003eHI93755-01\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\u003ctd\u003eHanna Instruments\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\u003ctd\u003eAlkalinity\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd\u003e\u003cstrong\u003eFormat\u003c\/strong\u003e\u003c\/td\u003e\u003ctd\u003eLiquid (dropper bottles)\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd\u003e\u003cstrong\u003eNumber of tests\u003c\/strong\u003e\u003c\/td\u003e\u003ctd\u003e100\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\u003ctd\u003e0–500 mg\/L CaCO3\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd\u003e\u003cstrong\u003eMethod\u003c\/strong\u003e\u003c\/td\u003e\u003ctd\u003eColorimetric\u003c\/td\u003e\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Hanna","offers":[{"title":"Default Title","offer_id":54378483843419,"sku":"01ESHI93755-01","price":36.34,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0990\/9600\/2907\/files\/21268.jpg?v=1792146639"},{"product_id":"cubetas-para-fotometros-lovibond","title":"Lovibond 24 mm round cuvette with lid for MD100, MD110 and MD200 photometers – 197620 (single)","description":"\u003cp\u003eIn a photometer the light passes through the cuvette, so scratches and marks on the glass affect the chlorine, pH and other readings. If it is no longer clear after cleaning, it should be replaced.\u003c\/p\u003e\n\u003cp\u003eThis is the original Lovibond round cuvette for the MD100, MD110 and MD200 photometers. Lovibond sells it in boxes of 12; at Quimipool we sell it individually, with lid and sealing ring.\u003c\/p\u003e\n\u003ch2\u003eFeatures\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eLovibond reference\u003c\/strong\u003e: 197620 (box of 12).\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eMaterial\u003c\/strong\u003e: glass.\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eSize\u003c\/strong\u003e: 24 mm diameter; 10 ml sample.\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eSupply\u003c\/strong\u003e: single unit, with lid and sealing ring.\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eCompatibility\u003c\/strong\u003e: Lovibond MD100, MD110 and MD200 photometers.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eUse\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eHold the cuvette by the top and wipe it with the cloth before measuring.\u003c\/li\u003e\n\u003cli\u003eReplace the cuvette if it is scratched: scratches affect the reading.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eRelated accessories (Lovibond code)\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eSealing rings for 24 mm cuvettes (set of 12): 197626.\u003c\/li\u003e\n\u003cli\u003eCleaning cloth: 197635.\u003c\/li\u003e\n\u003cli\u003eStand for 6 cuvettes of 24 mm: 418951.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Lovibond","offers":[{"title":"Default Title","offer_id":54378485088603,"sku":"01IES19029","price":12.95,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0990\/9600\/2907\/files\/lovibond-6278-estudio_3a84e281-ccbb-4740-9cc6-a04786f7f408.png?v=1793374658"},{"product_id":"reactivo-en-polvo-cloro-libre-300-test","title":"Reagent powder Hanna Free Chlorine 300 test","description":"\u003cp\u003eFree chlorine is the part of the chlorine that actually disinfects. If the reading is wrong, you end up adding too much chlorine (odour, irritation, wasted product) or too little (cloudy water and algae). HI93701-03 is Hanna's original reagent for measuring free chlorine.\u003c\/p\u003e\u003ch2\u003eWhat's included\u003c\/h2\u003e\u003cul\u003e\u003cli\u003ePowder reagent in sachets.\u003c\/li\u003e\u003cli\u003eEnough for \u003cstrong\u003e300 tests\u003c\/strong\u003e.\u003c\/li\u003e\u003cli\u003eMarked with lot number and expiry date.\u003c\/li\u003e\u003c\/ul\u003e\u003ch2\u003eCompatible meters\u003c\/h2\u003e\u003cp\u003eSuitable for Hanna benchtop and portable photometers that measure free chlorine. Models listed by Hanna: HI97710, HI97711, HI97734, HI97745, HS94104C, HI97101 and HS94101C. Also used in the HI701 Checker.\u003c\/p\u003e\u003ch2\u003eTips for a reliable reading\u003c\/h2\u003e\u003cul\u003e\u003cli\u003eFollow the procedure in your meter's manual: the order of reagents and the reaction time vary by parameter.\u003c\/li\u003e\u003cli\u003eAlways add the whole sachet: an incomplete dose gives a false reading.\u003c\/li\u003e\u003cli\u003eClean and dry the outside of the cuvette before inserting it: a fingerprint or a drop will distort the reading.\u003c\/li\u003e\u003cli\u003eDo not use the reagent after its expiry date.\u003c\/li\u003e\u003c\/ul\u003e\u003ch2\u003eStorage\u003c\/h2\u003e\u003cp\u003eStore the reagent in a dry place, tightly closed and away from sunlight. An expired or poorly stored reagent is one of the most common causes of incorrect readings.\u003c\/p\u003e\u003ch2\u003eTechnical specifications\u003c\/h2\u003e\u003ctable\u003e\u003ctbody\u003e\u003ctr\u003e\u003ctd\u003e\u003cstrong\u003eReference\u003c\/strong\u003e\u003c\/td\u003e\u003ctd\u003eHI93701-03\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\u003ctd\u003eHanna Instruments\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\u003ctd\u003eFree chlorine\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003e\u003cstrong\u003eFormat\u003c\/strong\u003e\u003c\/td\u003e\u003ctd\u003ePowder (sachets)\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003e\u003cstrong\u003eNumber of tests\u003c\/strong\u003e\u003c\/td\u003e\u003ctd\u003e300\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\u003ctd\u003e0.00–5.00 mg\/L\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003e\u003cstrong\u003eMethod\u003c\/strong\u003e\u003c\/td\u003e\u003ctd\u003eDPD, adaptation of USEPA method 330.5 and Standard Method 4500-Cl G\u003c\/td\u003e\u003c\/tr\u003e\u003c\/tbody\u003e\u003c\/table\u003e\u003cp\u003eAlso available: HI93701-01 (100 tests).\u003c\/p\u003e","brand":"Hanna","offers":[{"title":"Default Title","offer_id":54378571071835,"sku":"01ESHI93701-03","price":94.95,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0990\/9600\/2907\/files\/21242.jpg?v=1792147993"},{"product_id":"reactivo-phenol-ph-fotmetro-astralpool","title":"Astralpool Palintest Phenol Red pH tablets AP130 – 250 pcs for photometers","description":"\u003cp\u003eWith a high pH, chlorine loses effectiveness. This is the Palintest Phenol Red tablet for measuring pH with a photometer, with a range of 6.5 to 8.4.\u003c\/p\u003e\n\u003ch2\u003eWhat it measures and what to aim for\u003c\/h2\u003e\n\u003cp\u003eIt measures \u003cstrong\u003epH\u003c\/strong\u003e. Keep it between \u003cstrong\u003e7.2 and 7.4\u003c\/strong\u003e: chlorine then works at its best and less product is used.\u003c\/p\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e250 tablets for photometers. They are crushed in the tube to release the reagent.\u003c\/li\u003e\n\u003cli\u003eRange: pH 6.5–8.4.\u003c\/li\u003e\n\u003cli\u003eManufacturer code: AP130 (Palintest). Astralpool code: 41918.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003ePooltester or photometer?\u003c\/h2\u003e\n\u003cp\u003eThis tablet is for photometers. Palintest states that Rapid and comparator tablets are not suitable for photometers. For a Pooltester use \u003ca href=\"https:\/\/www.quimipool.com\/en\/products\/phenol-reagent-ph-pooltester-astralpool\"\u003ePhenol Red Rapid AT130\u003c\/a\u003e.\u003c\/p\u003e\n\u003ch2\u003eHow to use\u003c\/h2\u003e\n\u003col\u003e\n\u003cli\u003eFill the tube with sample exactly to the 10 mL mark.\u003c\/li\u003e\n\u003cli\u003eAdd one Phenol Red tablet, crush it and mix.\u003c\/li\u003e\n\u003cli\u003eRead on the photometer: that is the pH.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Astralpool","offers":[{"title":"Default Title","offer_id":54378583687515,"sku":"01ES41918","price":13.48,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0990\/9600\/2907\/files\/astralpool-reactivo-3-revisada.png?v=1795020779"},{"product_id":"reactivo-dpd-1-fotmetro-astralpool","title":"Astralpool Palintest DPD 1 free chlorine tablets AP011 – 250 pcs for photometers","description":"\u003cp\u003eA photometer gives a numerical free chlorine reading, without depending on how each person interprets a colour. This is the Palintest DPD 1 tablet for photometers, with a range of 0 to 5 mg\/L.\u003c\/p\u003e\n\u003ch2\u003eWhat it measures and what to aim for\u003c\/h2\u003e\n\u003cp\u003eIt measures \u003cstrong\u003efree chlorine\u003c\/strong\u003e. Keep free chlorine between \u003cstrong\u003e1 and 1.5 ppm\u003c\/strong\u003e and pH between 7.2 and 7.4.\u003c\/p\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e250 tablets for photometers. They are crushed in the tube to release the reagent.\u003c\/li\u003e\n\u003cli\u003eRange: 0–5 mg\/L free chlorine.\u003c\/li\u003e\n\u003cli\u003eManufacturer code: AP011 (Palintest). Astralpool code: 41919.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003ePooltester or photometer?\u003c\/h2\u003e\n\u003cp\u003eThis tablet is for photometers. Palintest states that Rapid and comparator tablets are not suitable for photometers. For a Pooltester use \u003ca href=\"https:\/\/www.quimipool.com\/en\/products\/reagent-dpd-1-pooltester-astralpool\"\u003eDPD 1 Rapid AT050\u003c\/a\u003e.\u003c\/p\u003e\n\u003ch2\u003eHow to use\u003c\/h2\u003e\n\u003col\u003e\n\u003cli\u003eFill the tube with sample and zero (blank) the photometer.\u003c\/li\u003e\n\u003cli\u003eEmpty the tube leaving a few drops, add one DPD 1 tablet and crush it.\u003c\/li\u003e\n\u003cli\u003eTop up with sample to the 10 mL mark, cap, mix and read: that is free chlorine.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Astralpool","offers":[{"title":"Default Title","offer_id":54378583720283,"sku":"01ES41919","price":14.57,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0990\/9600\/2907\/files\/astralpool-reactivo-1-revisada.png?v=1795020742"},{"product_id":"reactivo-en-polvo-para-hierro-50-test","title":"Hanna iron powder reagent, low range (100 tests)","description":"\u003cp\u003eDissolved iron, common in well water, turns the water brown or green when chlorinated and leaves stains on the pool lining. Measuring it before filling or treating prevents stains that are hard to remove. The HI93746-01 is Hanna's original reagent for measuring iron.\u003c\/p\u003e\n\u003ch2\u003eWhat's included\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003ePowder reagent, in sachets.\u003c\/li\u003e\n\u003cli\u003eQuantity for \u003cstrong\u003e100 tests\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003eMarked with batch number and expiry date.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eCompatible meters\u003c\/h2\u003e\n\u003cp\u003eSuitable for Hanna benchtop and portable photometers that measure iron.\u003c\/p\u003e\n\u003ch2\u003eTips for a reliable reading\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eFollow the procedure in your meter's manual: the order of the reagents and the reaction time vary by parameter.\u003c\/li\u003e\n\u003cli\u003eAlways add the whole sachet: an incomplete dose gives a false reading.\u003c\/li\u003e\n\u003cli\u003eClean and dry the outside of the cuvette before inserting it: a fingerprint or a drop alters the reading.\u003c\/li\u003e\n\u003cli\u003eDo not use the reagent after its expiry date.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eStorage\u003c\/h2\u003e\n\u003cp\u003eStore the reagent in a dry place, tightly closed and away from sunlight. An expired or poorly stored reagent is one of the most common causes of incorrect readings.\u003c\/p\u003e\n\u003ch2\u003eTechnical specifications\u003c\/h2\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\u003ctd\u003e\u003cstrong\u003eReference\u003c\/strong\u003e\u003c\/td\u003e\u003ctd\u003eHI93746-01\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\u003ctd\u003eHanna Instruments\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\u003ctd\u003eIron (low range)\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd\u003e\u003cstrong\u003eFormat\u003c\/strong\u003e\u003c\/td\u003e\u003ctd\u003ePowder (sachets)\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd\u003e\u003cstrong\u003eNumber of tests\u003c\/strong\u003e\u003c\/td\u003e\u003ctd\u003e100\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\u003ctd\u003e0.00–1.60 mg\/L\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd\u003e\u003cstrong\u003eMethod\u003c\/strong\u003e\u003c\/td\u003e\u003ctd\u003eTPTZ\u003c\/td\u003e\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cp\u003eAlso available: HI93746-03 (300 tests).\u003c\/p\u003e","brand":"Hanna","offers":[{"title":"Default Title","offer_id":54378662396251,"sku":"01ESHI93746-01","price":74.9,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0990\/9600\/2907\/files\/25111.jpg?v=1792148495"},{"product_id":"reactivo-en-polvo-para-cobre-rango-bajo-25-test","title":"Copper reagent powder (low range) 25 test","description":"\u003cp\u003eCopper gets into the water from some algaecides, ionisers or corrosion of metal parts. In excess it leaves green or bluish stains and can tint hair. Measuring it warns you before they appear. The HI747-25 is Hanna's original reagent for measuring copper.\u003c\/p\u003e\n\u003ch2\u003eWhat's included\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003ePowder reagent, in sachets.\u003c\/li\u003e\n\u003cli\u003eQuantity for \u003cstrong\u003e25 tests\u003c\/strong\u003e.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eCompatible meters\u003c\/h2\u003e\n\u003cp\u003eIt is the reagent for Hanna's Checker HI747.\u003c\/p\u003e\n\u003ch2\u003eTips for a reliable reading\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eFollow the procedure in your meter's manual: the order of the reagents and the reaction time vary by parameter.\u003c\/li\u003e\n\u003cli\u003eAlways add the whole sachet: an incomplete dose gives a false reading.\u003c\/li\u003e\n\u003cli\u003eClean and dry the outside of the cuvette before inserting it: a fingerprint or a drop alters the reading.\u003c\/li\u003e\n\u003cli\u003eDo not use the reagent after its expiry date.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eStorage\u003c\/h2\u003e\n\u003cp\u003eStore the reagent in a dry place, tightly closed and away from sunlight. An expired or poorly stored reagent is one of the most common causes of incorrect readings.\u003c\/p\u003e\n\u003ch2\u003eTechnical specifications\u003c\/h2\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\u003ctd\u003e\u003cstrong\u003eReference\u003c\/strong\u003e\u003c\/td\u003e\u003ctd\u003eHI747-25\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\u003ctd\u003eHanna Instruments\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\u003ctd\u003eCopper (low range)\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd\u003e\u003cstrong\u003eFormat\u003c\/strong\u003e\u003c\/td\u003e\u003ctd\u003ePowder (sachets)\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd\u003e\u003cstrong\u003eNumber of tests\u003c\/strong\u003e\u003c\/td\u003e\u003ctd\u003e25\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\u003ctd\u003e0–999 µg\/L (ppb)\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd\u003e\u003cstrong\u003eMethod\u003c\/strong\u003e\u003c\/td\u003e\u003ctd\u003eBicinchoninate\u003c\/td\u003e\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Hanna","offers":[{"title":"Default Title","offer_id":54378772300123,"sku":"01ESHI747-25","price":20.55,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0990\/9600\/2907\/files\/21280.jpg?v=1792149841"},{"product_id":"reactivo-dpd-n1-cloro-libre-primelab-50-tabletas","title":"DPD Reagent No. 1 Free chlorine photometer PrimeLAB (50 tablets)","description":"\u003cul\u003e\r\n\u003cli\u003eDPD Reagent No. 1 for photometer\u003c\/li\u003e\r\n\u003cli\u003eManufacturer: PrimeLAB\u003c\/li\u003e\r\n\u003cli\u003e\u003cstrong\u003eParameter: Free chlorine\u003c\/strong\u003e\u003c\/li\u003e\r\n\u003cli\u003e\u003cstrong\u003eFormat: tablets\u003c\/strong\u003e\u003c\/li\u003e\r\n\u003cli\u003e\u003cstrong\u003eTest No.: 50\u003c\/strong\u003e\u003c\/li\u003e\r\n\u003cli\u003eIndividually sealed to guarantee an exact dosage and a long shelf life\u003c\/li\u003e\r\n\u003c\/ul\u003e","brand":"PrimeLAB","offers":[{"title":"Default Title","offer_id":54379149427035,"sku":"01IES12212","price":5.95,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0990\/9600\/2907\/files\/reactivo-dpd1-primelab-50-tabletas.png?v=1795010444"},{"product_id":"reactivo-dpd-n3-cloro-total-fotometro-primelab-250-tabletas","title":"DPD Reagent No. 3 Total Chlorine Photometer PrimeLAB (250 tablets)","description":"\u003cul\u003e\r\n\u003cli\u003eDPD reagent nº3 (total chlorine).\u003c\/li\u003e\r\n\u003cli\u003e\u003cstrong\u003eFor photometer.\u003c\/strong\u003e\u003c\/li\u003e\r\n\u003cli\u003eFormat: box with 250 tablets.\u003c\/li\u003e\r\n\u003cli\u003eIndividually sealed to ensure accurate dosing and long shelf life.\u003c\/li\u003e\r\n\u003c\/ul\u003e","brand":"PrimeLAB","offers":[{"title":"Default Title","offer_id":54379150967131,"sku":"01IES209060D3","price":14.9,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0990\/9600\/2907\/files\/24277.jpg?v=1792151102"},{"product_id":"reactivo-phenol-red-fotometro-primelab-250-tabletas","title":"Phenol Red photometer reagent PrimeLAB (250 tablets)","description":"\u003cul\u003e\r\n\u003cli\u003ePhenol Red Reagent.\u003c\/li\u003e\r\n\u003cli\u003e\u003cstrong\u003eFor photometer.\u003c\/strong\u003e\u003c\/li\u003e\r\n\u003cli\u003eFormat: box with 250 tablets.\u003c\/li\u003e\r\n\u003cli\u003eIndividually sealed to ensure accurate dosage and long shelf life.\u003c\/li\u003e\r\n\u003c\/ul\u003e","brand":"PrimeLAB","offers":[{"title":"Default Title","offer_id":54379150999899,"sku":"01IES209060PH","price":14.75,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0990\/9600\/2907\/files\/24278.jpg?v=1792151103"},{"product_id":"reactivo-dpd-n1-cloro-libre-fotometro-primelab-250-tabletas","title":"DPD Reagent No. 1 Free chlorine photometer PrimeLAB (250 tablets)","description":"\u003cul\u003e\r\n\u003cli\u003eDPD reagent nº1 (free chlorine).\u003c\/li\u003e\r\n\u003cli\u003e\u003cstrong\u003eFor photometer.\u003c\/strong\u003e\u003c\/li\u003e\r\n\u003cli\u003eFormat: box with 250 tablets.\u003c\/li\u003e\r\n\u003cli\u003eIndividually sealed to ensure accurate dosing and long shelf life.\u003c\/li\u003e\r\n\u003c\/ul\u003e","brand":"PrimeLAB","offers":[{"title":"Default Title","offer_id":54379151098203,"sku":"01IES209060D1","price":14.9,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0990\/9600\/2907\/files\/24276.jpg?v=1792151105"},{"product_id":"reactivo-liquido-hanna-para-cloro-libre-100-test","title":"Liquid reagent Hanna for Free Chlorine 100 tests","description":"\u003cp\u003eFree chlorine is the part of the chlorine that disinfects. If the reading is wrong, you will end up adding too much chlorine (smell, irritation, cost) or too little (cloudy water and algae). The HS93701-F1 is Hanna's original reagent for measuring free chlorine.\u003c\/p\u003e\n\u003ch2\u003eWhat's included\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eLiquid reagent, in dropper bottles.\u003c\/li\u003e\n\u003cli\u003e1 bottle of reagent A (yellow cap) and 1 of reagent B (blue cap). Per analysis: 3 drops of each.\u003c\/li\u003e\n\u003cli\u003eQuantity for \u003cstrong\u003e100 tests\u003c\/strong\u003e.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eCompatible meters\u003c\/h2\u003e\n\u003cp\u003eSuitable for Hanna benchtop and portable photometers that measure free chlorine. Models listed by Hanna: HI97701, HI97710, HI97711, HI971044, HI97734, HI97745, HS94104C and HI97101. Also used in the Checker HI701.\u003c\/p\u003e\n\u003ch2\u003eTips for a reliable reading\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eFollow the procedure in your meter's manual: the order of the reagents and the reaction time vary by parameter.\u003c\/li\u003e\n\u003cli\u003eClean and dry the outside of the cuvette before inserting it: a fingerprint or a drop alters the reading.\u003c\/li\u003e\n\u003cli\u003eDo not use the reagent after its expiry date.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eStorage\u003c\/h2\u003e\n\u003cp\u003eStore the reagent in a dry place, tightly closed and away from sunlight. An expired or poorly stored reagent is one of the most common causes of incorrect readings.\u003c\/p\u003e\n\u003ch2\u003eTechnical specifications\u003c\/h2\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\u003ctd\u003e\u003cstrong\u003eReference\u003c\/strong\u003e\u003c\/td\u003e\u003ctd\u003eHS93701-F1\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\u003ctd\u003eHanna Instruments\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\u003ctd\u003eFree chlorine\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd\u003e\u003cstrong\u003eFormat\u003c\/strong\u003e\u003c\/td\u003e\u003ctd\u003eLiquid (dropper bottles)\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd\u003e\u003cstrong\u003eNumber of tests\u003c\/strong\u003e\u003c\/td\u003e\u003ctd\u003e100\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\u003ctd\u003e0.00–5.00 mg\/L\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd\u003e\u003cstrong\u003eMethod\u003c\/strong\u003e\u003c\/td\u003e\u003ctd\u003eDPD, adaptation of USEPA method 330.5 and Standard Method 4500-Cl G\u003c\/td\u003e\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cp\u003eAlso available: HI93701-F (300 tests).\u003c\/p\u003e","brand":"Hanna","offers":[{"title":"Default Title","offer_id":54379155816795,"sku":"01ESHS93701-F1","price":14.9,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0990\/9600\/2907\/files\/18470.jpg?v=1792151199"},{"product_id":"cubetas-turbidimetro-lovibond-turbicheck-tb-211-ir-24-mm","title":"Lovibond 24 mm cuvette with black lid for TB 211 IR Turbicheck turbidimeter – 197655 (single)","description":"\u003cp\u003eIn a turbidimeter the light passes through the cuvette, so scratches and marks on the glass affect the turbidity reading. When the cuvette no longer stays clean and clear, it should be replaced.\u003c\/p\u003e\n\u003cp\u003eThis is the original Lovibond cuvette for the TB 211 IR Turbicheck turbidimeter, with black lid. Lovibond sells it in boxes of 12; at Quimipool we sell it individually.\u003c\/p\u003e\n\u003ch2\u003eFeatures\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eLovibond reference\u003c\/strong\u003e: 197655\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eSize\u003c\/strong\u003e: 24 mm diameter and 55 mm high.\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eLid\u003c\/strong\u003e: black, included.\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eCompatibility\u003c\/strong\u003e: Lovibond TB 211 IR Turbicheck turbidimeter.\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eSupply\u003c\/strong\u003e: single unit.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eUse\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eHold the cuvette by the top and wipe it with the cloth before each measurement.\u003c\/li\u003e\n\u003cli\u003eReplace the cuvette if it is scratched: scratches affect the reading.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eRelated accessories (Lovibond code)\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eT-CAL turbidity standards set (\u0026lt;0.1, 20, 200 and 800 NTU): 194150.\u003c\/li\u003e\n\u003cli\u003eCleaning cloth: 197635.\u003c\/li\u003e\n\u003cli\u003eSample chamber lid: 19801119.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Lovibond","offers":[{"title":"Default Title","offer_id":54379160863067,"sku":"01IES197655","price":16.9,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0990\/9600\/2907\/files\/lovibond-original-01IES197655-lovibond-cubeta-estudio-1.jpg?v=1793374602"},{"product_id":"reactivo-alcalinidad-fotometro-astralpool","title":"Reagent Alkalinity Photometer Astralpool","description":"\u003cul\u003e\r\n\u003cli\u003eAlkalinity Reagent\u003c\/li\u003e\r\n\u003cli\u003eManufacturer: Palintest\u003c\/li\u003e\r\n\u003cli\u003e\u003cstrong\u003eParameter: Alkalinity\u003c\/strong\u003e\u003c\/li\u003e\r\n\u003cli\u003e\u003cstrong\u003eFormat: 250 tablets\u003c\/strong\u003e\u003c\/li\u003e\r\n\u003cli\u003eIndividually sealed to guarantee an exact dosage and a long shelf life\u003c\/li\u003e\r\n\u003cli\u003eValid for photometers Astralpool\u003c\/li\u003e\r\n\u003c\/ul\u003e","brand":"Astralpool","offers":[{"title":"Default Title","offer_id":54379175444827,"sku":"01ES43410","price":59.0,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0990\/9600\/2907\/files\/astralpool-reactivo-5-revisada.png?v=1795020761"},{"product_id":"reactivo-dureza-fotometro-astralpool","title":"Reagent Hardness Photometer Astralpool","description":"\u003cul\u003e\r\n\u003cli\u003eHardness Reagent\u003c\/li\u003e\r\n\u003cli\u003eManufacturer: Palintest\u003c\/li\u003e\r\n\u003cli\u003e\u003cstrong\u003eParameter: Hardness\u003c\/strong\u003e\u003c\/li\u003e\r\n\u003cli\u003e\u003cstrong\u003eFormat: 250 tablets of Reagent No. 1 and 250 tablets of Reagent No. 2\u003c\/strong\u003e\u003c\/li\u003e\r\n\u003cli\u003eIndividually sealed to guarantee an exact dosage and a long shelf life\u003c\/li\u003e\r\n\u003cli\u003eValid for photometers Astralpool\u003c\/li\u003e\r\n\u003c\/ul\u003e","brand":"Astralpool","offers":[{"title":"Default Title","offer_id":54379175543131,"sku":"01ES49676","price":139.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0990\/9600\/2907\/files\/astralpool-reactivo-6-revisada.png?v=1795020755"},{"product_id":"solucin-verificacin-hanna-para-checker-cloro-libre-hi701-0-a-250-ppm","title":"Verification solution Hanna for HI701 Free Chlorine Checker (0 to 2.50 ppm)","description":"\u003cp\u003eWith use, any meter can drift without you noticing, and every subsequent reading will be wrong. With the HI701-11 you can check on the spot whether your Checker HI701 is still measuring correctly, without reagents or samples.\u003c\/p\u003e\n\u003ch2\u003eWhat's included\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eA sealed cuvette for zeroing the meter.\u003c\/li\u003e\n\u003cli\u003eA coloured standard cuvette equivalent to 1.00 ± 0.05 ppm free chlorine at 25 °C.\u003c\/li\u003e\n\u003cli\u003eCertificate of analysis with batch number, product code and expiry date.\u003c\/li\u003e\n\u003cli\u003eReusable.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eHow to use\u003c\/h2\u003e\n\u003cp\u003eZero the meter with the sealed cuvette and then read the standard cuvette. If the reading is within the reference value, the meter is measuring correctly; if it is outside, check the cuvette and the meter or contact us.\u003c\/p\u003e\n\u003ch2\u003eTechnical specifications\u003c\/h2\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\u003ctd\u003e\u003cstrong\u003eReference\u003c\/strong\u003e\u003c\/td\u003e\u003ctd\u003eHI701-11\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\u003ctd\u003eHanna Instruments\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd\u003e\u003cstrong\u003eCompatibility\u003c\/strong\u003e\u003c\/td\u003e\u003ctd\u003eChecker HI701\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\u003ctd\u003e0.00–2.50 ppm\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd\u003e\u003cstrong\u003eReference value\u003c\/strong\u003e\u003c\/td\u003e\u003ctd\u003e1.00 ± 0.05 ppm free chlorine\u003c\/td\u003e\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Hanna","offers":[{"title":"Default Title","offer_id":54379527864667,"sku":"01ESHI701-11","price":27.82,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0990\/9600\/2907\/files\/20637.jpg?v=1792152243"},{"product_id":"cubetas-de-cristal-y-tapas-de-cubetas-para-checker-2-ud","title":"Glass cuvettes and cuvette lids for checker, 2 pcs","description":"\u003cp\u003eThe cuvette is part of the measurement. A scratched or dirty cuvette, or one that does not match your meter, gives wrong readings even when the reagent is fine. When yours is scratched or broken, replace it with the original from Hanna.\u003c\/p\u003e\n\u003ch2\u003eWhat's included\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e2 glass cuvettes of 10 mL with their caps.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eCompatible meters\u003c\/h2\u003e\n\u003cp\u003eHanna Checker mini-photometers.\u003c\/p\u003e\n\u003ch2\u003eTips for a reliable reading\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eAvoid scratching the cuvette and keep it clean.\u003c\/li\u003e\n\u003cli\u003eDo not touch the walls with your fingers; clean it with a soft, purpose-made cloth.\u003c\/li\u003e\n\u003cli\u003eClose the cuvette during measurement to prevent the sample from evaporating.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical specifications\u003c\/h2\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\u003ctd\u003e\u003cstrong\u003eReference\u003c\/strong\u003e\u003c\/td\u003e\u003ctd\u003eHI731315\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\u003ctd\u003eHanna Instruments\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd\u003e\u003cstrong\u003eContents\u003c\/strong\u003e\u003c\/td\u003e\u003ctd\u003e2 glass cuvettes of 10 mL with their caps\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd\u003e\u003cstrong\u003eVolume\u003c\/strong\u003e\u003c\/td\u003e\u003ctd\u003e10 mL\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd\u003e\u003cstrong\u003eCompatibility\u003c\/strong\u003e\u003c\/td\u003e\u003ctd\u003eHanna Checker mini-photometers\u003c\/td\u003e\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Hanna","offers":[{"title":"Default Title","offer_id":54379535270235,"sku":"01ESHI731315","price":15.95,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0990\/9600\/2907\/files\/20675.jpg?v=1792152267"},{"product_id":"reactivo-hanna-para-dixido-de-cloro-100-test","title":"Reagent Hanna for Chlorine Dioxide (100 test)","description":"\u003cp\u003eChlorine dioxide is used as a disinfectant in drinking water and for legionella control. Measuring its residual confirms that the dosing is correct. The HI96779-01 is Hanna's original reagent for measuring chlorine dioxide.\u003c\/p\u003e\n\u003ch2\u003eWhat's included\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e1 bottle of reagent A (liquid) and 100 sachets of reagent B (powder).\u003c\/li\u003e\n\u003cli\u003eQuantity for \u003cstrong\u003e100 tests\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003eMarked with batch number and expiry date.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eCompatible meters\u003c\/h2\u003e\n\u003cp\u003eSuitable for Hanna benchtop and portable photometers that measure chlorine dioxide.\u003c\/p\u003e\n\u003ch2\u003eTips for a reliable reading\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eFollow the procedure in your meter's manual: the order of the reagents and the reaction time vary by parameter.\u003c\/li\u003e\n\u003cli\u003eClean and dry the outside of the cuvette before inserting it: a fingerprint or a drop alters the reading.\u003c\/li\u003e\n\u003cli\u003eDo not use the reagent after its expiry date.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eStorage\u003c\/h2\u003e\n\u003cp\u003eStore the reagent in a dry place, tightly closed and away from sunlight. An expired or poorly stored reagent is one of the most common causes of incorrect readings.\u003c\/p\u003e\n\u003ch2\u003eTechnical specifications\u003c\/h2\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\u003ctd\u003e\u003cstrong\u003eReference\u003c\/strong\u003e\u003c\/td\u003e\u003ctd\u003eHI96779-01\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\u003ctd\u003eHanna Instruments\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\u003ctd\u003eChlorine dioxide\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd\u003e\u003cstrong\u003eFormat\u003c\/strong\u003e\u003c\/td\u003e\u003ctd\u003eLiquid + powder\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd\u003e\u003cstrong\u003eNumber of tests\u003c\/strong\u003e\u003c\/td\u003e\u003ctd\u003e100\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\u003ctd\u003e0.00–2.00 mg\/L\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd\u003e\u003cstrong\u003eMethod\u003c\/strong\u003e\u003c\/td\u003e\u003ctd\u003eDPD\u003c\/td\u003e\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cp\u003eAlso available: HI96779-03 (300 tests).\u003c\/p\u003e","brand":"Hanna","offers":[{"title":"Default Title","offer_id":54379804983643,"sku":"01ESHI96779-01","price":67.91,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0990\/9600\/2907\/files\/25107.jpg?v=1792154064"},{"product_id":"reactivo-hanna-para-dixido-de-cloro-300-test","title":"Reagent Hanna for Chlorine Dioxide (300 test)","description":"\u003cp\u003eChlorine dioxide is used as a disinfectant in drinking water and for legionella control. Measuring its residual confirms that the dosing is correct. The HI96779-03 is Hanna's original reagent for measuring chlorine dioxide.\u003c\/p\u003e\n\u003ch2\u003eWhat's included\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e3 bottles of reagent A (liquid) and 300 sachets of reagent B (powder).\u003c\/li\u003e\n\u003cli\u003eQuantity for \u003cstrong\u003e300 tests\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003eMarked with batch number and expiry date.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eCompatible meters\u003c\/h2\u003e\n\u003cp\u003eSuitable for Hanna benchtop and portable photometers that measure chlorine dioxide.\u003c\/p\u003e\n\u003ch2\u003eTips for a reliable reading\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eFollow the procedure in your meter's manual: the order of the reagents and the reaction time vary by parameter.\u003c\/li\u003e\n\u003cli\u003eClean and dry the outside of the cuvette before inserting it: a fingerprint or a drop alters the reading.\u003c\/li\u003e\n\u003cli\u003eDo not use the reagent after its expiry date.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eStorage\u003c\/h2\u003e\n\u003cp\u003eStore the reagent in a dry place, tightly closed and away from sunlight. An expired or poorly stored reagent is one of the most common causes of incorrect readings.\u003c\/p\u003e\n\u003ch2\u003eTechnical specifications\u003c\/h2\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\u003ctd\u003e\u003cstrong\u003eReference\u003c\/strong\u003e\u003c\/td\u003e\u003ctd\u003eHI96779-03\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\u003ctd\u003eHanna Instruments\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\u003ctd\u003eChlorine dioxide\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd\u003e\u003cstrong\u003eFormat\u003c\/strong\u003e\u003c\/td\u003e\u003ctd\u003eLiquid + powder\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd\u003e\u003cstrong\u003eNumber of tests\u003c\/strong\u003e\u003c\/td\u003e\u003ctd\u003e300\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\u003ctd\u003e0.00–2.00 mg\/L\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd\u003e\u003cstrong\u003eMethod\u003c\/strong\u003e\u003c\/td\u003e\u003ctd\u003eDPD\u003c\/td\u003e\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cp\u003eAlso available: HI96779-01 (100 tests).\u003c\/p\u003e","brand":"Hanna","offers":[{"title":"Default Title","offer_id":54379806458203,"sku":"01ESHI96779-03","price":195.52,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0990\/9600\/2907\/files\/25108.jpg?v=1792154105"},{"product_id":"reactivo-en-polvo-hanna-para-fosfatos-rango-bajo-100-test","title":"Powder reagent Hanna for Phosphate low range (100 test)","description":"\u003cp\u003ePhosphates are food for algae. With high phosphates, the water can turn green even when the chlorine is at the right level. Measuring them tells you whether that is the problem and whether it is worth treating. The HI93713-01 is Hanna's original reagent for measuring phosphates.\u003c\/p\u003e\n\u003ch2\u003eWhat's included\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003ePowder reagent, in sachets.\u003c\/li\u003e\n\u003cli\u003eQuantity for \u003cstrong\u003e100 tests\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003eMarked with batch number and expiry date.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eCompatible meters\u003c\/h2\u003e\n\u003cp\u003eSuitable for Hanna benchtop and portable photometers that measure phosphates.\u003c\/p\u003e\n\u003ch2\u003eTips for a reliable reading\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eFollow the procedure in your meter's manual: the order of the reagents and the reaction time vary by parameter.\u003c\/li\u003e\n\u003cli\u003eAlways add the whole sachet: an incomplete dose gives a false reading.\u003c\/li\u003e\n\u003cli\u003eClean and dry the outside of the cuvette before inserting it: a fingerprint or a drop alters the reading.\u003c\/li\u003e\n\u003cli\u003eDo not use the reagent after its expiry date.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eStorage\u003c\/h2\u003e\n\u003cp\u003eStore the reagent in a dry place, tightly closed and away from sunlight. An expired or poorly stored reagent is one of the most common causes of incorrect readings.\u003c\/p\u003e\n\u003ch2\u003eTechnical specifications\u003c\/h2\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\u003ctd\u003e\u003cstrong\u003eReference\u003c\/strong\u003e\u003c\/td\u003e\u003ctd\u003eHI93713-01\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\u003ctd\u003eHanna Instruments\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\u003ctd\u003ePhosphates (low range)\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd\u003e\u003cstrong\u003eFormat\u003c\/strong\u003e\u003c\/td\u003e\u003ctd\u003ePowder (sachets)\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd\u003e\u003cstrong\u003eNumber of tests\u003c\/strong\u003e\u003c\/td\u003e\u003ctd\u003e100\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\u003ctd\u003e0.00–2.50 mg\/L\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd\u003e\u003cstrong\u003eMethod\u003c\/strong\u003e\u003c\/td\u003e\u003ctd\u003eAscorbic acid\u003c\/td\u003e\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cp\u003eAlso available: HI93713-03 (300 tests).\u003c\/p\u003e","brand":"Hanna","offers":[{"title":"Default Title","offer_id":54379806589275,"sku":"01ESHI93713-01","price":44.9,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0990\/9600\/2907\/files\/25109.jpg?v=1792154106"},{"product_id":"reactivo-en-polvo-hanna-para-fosfatos-rango-bajo-300-test","title":"Powder reagent Hanna for Phosphate low range (300 test)","description":"\u003cp\u003ePhosphates are food for algae. With high phosphates, the water can turn green even when the chlorine is at the right level. Measuring them tells you whether that is the problem and whether it is worth treating. The HI93713-03 is Hanna's original reagent for measuring phosphates.\u003c\/p\u003e\n\u003ch2\u003eWhat's included\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003ePowder reagent, in sachets.\u003c\/li\u003e\n\u003cli\u003eQuantity for \u003cstrong\u003e300 tests\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003eMarked with batch number and expiry date.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eCompatible meters\u003c\/h2\u003e\n\u003cp\u003eSuitable for Hanna benchtop and portable photometers that measure phosphates.\u003c\/p\u003e\n\u003ch2\u003eTips for a reliable reading\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eFollow the procedure in your meter's manual: the order of the reagents and the reaction time vary by parameter.\u003c\/li\u003e\n\u003cli\u003eAlways add the whole sachet: an incomplete dose gives a false reading.\u003c\/li\u003e\n\u003cli\u003eClean and dry the outside of the cuvette before inserting it: a fingerprint or a drop alters the reading.\u003c\/li\u003e\n\u003cli\u003eDo not use the reagent after its expiry date.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eStorage\u003c\/h2\u003e\n\u003cp\u003eStore the reagent in a dry place, tightly closed and away from sunlight. An expired or poorly stored reagent is one of the most common causes of incorrect readings.\u003c\/p\u003e\n\u003ch2\u003eTechnical specifications\u003c\/h2\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\u003ctd\u003e\u003cstrong\u003eReference\u003c\/strong\u003e\u003c\/td\u003e\u003ctd\u003eHI93713-03\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\u003ctd\u003eHanna Instruments\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\u003ctd\u003ePhosphates (low range)\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd\u003e\u003cstrong\u003eFormat\u003c\/strong\u003e\u003c\/td\u003e\u003ctd\u003ePowder (sachets)\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd\u003e\u003cstrong\u003eNumber of tests\u003c\/strong\u003e\u003c\/td\u003e\u003ctd\u003e300\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\u003ctd\u003e0.00–2.50 mg\/L\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd\u003e\u003cstrong\u003eMethod\u003c\/strong\u003e\u003c\/td\u003e\u003ctd\u003eAscorbic acid\u003c\/td\u003e\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cp\u003eAlso available: HI93713-01 (100 tests).\u003c\/p\u003e","brand":"Hanna","offers":[{"title":"Default Title","offer_id":54379806622043,"sku":"01ESHI93713-03","price":129.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0990\/9600\/2907\/files\/25110.jpg?v=1792154108"},{"product_id":"reactivo-lquido-hanna-pool-line-para-ph-100-test","title":"Liquid reagent Hanna Pool Line for pH (100 test)","description":"\u003cp\u003epH determines how effective the chlorine is and whether swimming is comfortable. With an unbalanced pH, chlorine loses effectiveness and the water irritates eyes and skin. At Quimipool we recommend keeping it between 7.2 and 7.4. The HI779-25 is Hanna's original reagent for measuring pH.\u003c\/p\u003e\n\u003ch2\u003eWhat's included\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eLiquid reagent, in dropper bottles.\u003c\/li\u003e\n\u003cli\u003eQuantity for \u003cstrong\u003e100 tests\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003eMarked with batch number and expiry date.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eCompatible meters\u003c\/h2\u003e\n\u003cp\u003eFor Hanna Pool Line photometric pH meters for pools.\u003c\/p\u003e\n\u003ch2\u003eTips for a reliable reading\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eFollow the procedure in your meter's manual: the order of the reagents and the reaction time vary by parameter.\u003c\/li\u003e\n\u003cli\u003eClean and dry the outside of the cuvette before inserting it: a fingerprint or a drop alters the reading.\u003c\/li\u003e\n\u003cli\u003eDo not use the reagent after its expiry date.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eStorage\u003c\/h2\u003e\n\u003cp\u003eStore the reagent in a dry place, tightly closed and away from sunlight. An expired or poorly stored reagent is one of the most common causes of incorrect readings.\u003c\/p\u003e\n\u003ch2\u003eTechnical specifications\u003c\/h2\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\u003ctd\u003e\u003cstrong\u003eReference\u003c\/strong\u003e\u003c\/td\u003e\u003ctd\u003eHI779-25\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\u003ctd\u003eHanna Instruments\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\u003ctd\u003epH\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd\u003e\u003cstrong\u003eFormat\u003c\/strong\u003e\u003c\/td\u003e\u003ctd\u003eLiquid (dropper bottles)\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd\u003e\u003cstrong\u003eNumber of tests\u003c\/strong\u003e\u003c\/td\u003e\u003ctd\u003e100\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\u003ctd\u003e6.3–8.6 pH\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd\u003e\u003cstrong\u003eMethod\u003c\/strong\u003e\u003c\/td\u003e\u003ctd\u003eColorimetric\u003c\/td\u003e\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Hanna","offers":[{"title":"Default Title","offer_id":54379806654811,"sku":"01ESHI779-25","price":26.9,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0990\/9600\/2907\/files\/25112.jpg?v=1792154110"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0990\/9600\/2907\/collections\/792.jpg?v=1792140007","url":"https:\/\/www.quimipool.com\/en\/collections\/reagents-and-accessories-for-photometers.oembed","provider":"Quimipool","version":"1.0","type":"link"}